• Respiratory care · Sep 2020

    Response of Home-Use Adaptive Pressure Modes to Simulated Transient Hypoventilation.

    • Frédéric Lofaso, Karl Leroux, Ghilas Boussaid, Hélène Prigent, and Bruno Louis.
    • Department of Clinical Physiology, AP-HP Hôpital Raymond Poincaré, Université de Versailles Saint Quentin en Yvelines, Garches, France. f.lofaso@aphp.fr.
    • Respir Care. 2020 Sep 1; 65 (9): 1258-1267.

    BackgroundAdaptive servoventilation (ASV) is a recently developed ventilation mode designed to stabilize ventilation in patients with central sleep apnea and Cheyne-Stokes respiration. Alternatively, modes aiming to maintain average ventilation over several breaths, such as average volume-assured pressure support (AVAPS) and intelligent volume-assured pressure support (iVAPS), could be efficient during ventilation instability by reducing central events. These modes are available on a variety of devices. This bench evaluation studied the response of these different modes and devices to simulated transient hypoventilation events.MethodsThree home ventilation devices operating in ASV modes (AirCurve S10 VAuto, ResMed; DreamStation autoSV, Philips; Prisma CR, Löwenstein) and 2 ventilators with the AVAPS mode (DreamStation BiPAP, Philips; Lumis iVAPS, ResMed) were evaluated during transient central hypopnea/hypoventilation simulations characterized by a constant breathing frequency of 15 breaths/min and a progressive decrease of tidal volume (VT) from 500 mL to 50 mL, in 18, 12, 9, and 6 breaths, respectively, followed by a progressive return to the baseline at the same rate.ResultsThe AirCurve S10 VAuto reacted to a VT decrease between 80% and 50% of baseline VT. DreamStation BiPAP and Prisma CR reacted when VT decreased to between 60% and 30% of baseline VT, whereas the AVAPS response to hypopnea occurred during the crescendo phase of hypopnea/hypoventilation VT. The iVAPS response was between that of the AirCurve S10 VAuto and the other ASV devices. Among the ASV devices, the minimum VT was higher with AirCurve S10 VAuto, followed by the Prisma CR and the DreamStation BiPAP. Minimum VT was not influenced by AVAPS and was improved by iVAPS without outperforming the AirCurve S10 VAuto. Maximum VT was increased by iVAPS, whereas ASV devices did not induce a significant VT overshoot.ConclusionsASV devices improved central hypopnea/hypoventilation events without inducing hyperpnea events and therefore were better adapted than AVAPS and iVAPS devices, with notable differences in their responses to hypoventilation events.Copyright © 2020 by Daedalus Enterprises.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…