- Richard Manber, Kris Thielemans, Brian F Hutton, Anna Barnes, Sébastien Ourselin, Simon Arridge, Celia O'Meara, Simon Wan, and David Atkinson.
- Division of Medicine, Centre for Medical Imaging, University College London, London, United Kingdom r.manber@ucl.ac.uk.
- J. Nucl. Med. 2015 Jun 1; 56 (6): 890-6.
UnlabelledRespiratory motion during PET acquisition may lead to blurring in resulting images and underestimation of uptake parameters. The advent of integrated PET/MR scanners allows us to exploit the integration of modalities, using high spatial resolution and high-contrast MR images to monitor and correct PET images degraded by motion. We proposed a practical, anatomy-independent MR-based correction strategy for PET data affected by respiratory motion and showed that it can improve image quality both for PET acquired simultaneously to the motion-capturing MR and for PET acquired up to 1 h earlier during a clinical scan.MethodsTo estimate the respiratory motion, our method needs only an extra 1-min dynamic MR scan, acquired at the end of the clinical PET/MR protocol. A respiratory signal was extracted directly from the PET list-mode data. This signal was used to gate the PET data and to construct a motion model built from the dynamic MR data. The estimated motion was then incorporated into the PET image reconstruction to obtain a single motion-corrected PET image. We evaluated our method in 2 steps. The PET-derived respiratory signal was compared with an MR measure of diaphragmatic displacement via a pencil-beam navigator. The motion-corrected images were compared with uncorrected images with visual inspection, line profiles, and standardized uptake value (SUV) in focally avid lesions.ResultsWe showed a strong correlation between the PET-derived and MR-derived respiratory signals for 9 patients, with a mean correlation of 0.89. We then showed 4 clinical case study examples ((18)F-FDG and (68)Ga-DOTATATE) using the motion-correction technique, demonstrating improvements in image sharpness and reduction of respiratory artifacts in scans containing pancreatic, liver, and lung lesions as well as cardiac scans. The mean increase in peak SUV (SUV(peak)) and maximum SUV (SUV(max)) in a patient with 4 pancreatic lesions was 23.1% and 34.5% in PET acquired simultaneously with motion-capturing MR, and 17.6% and 24.7% in PET acquired 50 min before as part of the clinical scan.ConclusionWe showed that a respiratory signal can be obtained from raw PET data and that the clinical PET image quality can be improved using only a short additional PET/MR acquisition. Our method does not need external respiratory hardware or modification of the normal clinical MR sequences.© 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.