• Zhonghua yi xue za zhi · Jul 2020

    [Application of urethral pressure profilometry in artificial urinary sphincter implantation].

    • L F Meng, X D Liu, M Wang, W Zhang, H M Hou, S Y Zhao, Y H Zhou, X Chu, J Y Wu, Y G Zhang, X M Wang, and J W Wang.
    • Department of Urology, Beijing Hospital, National Center of Gerontology/Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing 100730, China.
    • Zhonghua Yi Xue Za Zhi. 2020 Jul 14; 100 (26): 2044-2048.

    AbstractObjective: To investigate the changes of maximum urethral pressure (MUP) and maximum urethral closure pressure (MUCP) after artificial urethral sphincter (AUS) implantation and their prognostic value. Methods: The clinical data of patients who had undergone AUS implantation in multiple medical centers between March and July 2019 were retrospectively analyzed. Data of urethral pressure profilometry, pad usage, related scores and complications related to surgery were collected and compared. The primary endpoint was social continence (defined as 0-1 pad/d) 1 month after activation of the pump. Results: A total of five male patients were included in this study. Two underwent transurethral resection of the prostate for benign prostatic hyperplasia, two underwent radical prostatectomy for prostate cancer, and one underwent urethral reunion, urethral stricture dilatation and cystostomy due to trauma from traffic accident. All patients had different degrees of urinary incontinence. The results of preoperative urethral profilometry test showed that the MUP of five patients were 52, 53, 88, 32, and 66 cmH(2)O(1 cmH(2)O=0.098 kPa), respectively, and the MUCP were 17, 52, 62, 27, and 40 cmH(2)O, respectively. AUS implantation was performed. The intraoperative urethral pressure profilometry showed that the MUP were 53, 113, 50, 77, and 89 cmH(2)O in the inactivated state, and the MUCP were 50, 97, 31, 71, and 51 cmH(2)O, respectively. In the activated state, the MUP were 112, 174, 193, 121, and 120 cmH(2)O, and the MUCP were 109, 160, 175, 114, and 92 cmH(2)O, respectively. All patients met the social continence (0-1 pad/d) criterion. No complications were reported during the follow-up. Conclusions: The relationship between the range of intraoperative urethral pressure and the effect of urinary control can be gained by measuring the specific values of MUP and MUCP during AUS implantation and the post-operative effects, which provides as a data basis for standardizing AUS implantation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…