• J Clin Monit Comput · Oct 2021

    Anatomical and physiological variables influencing measurement of regional cerebral oxygen saturation by near infrared spectroscopy using the Sensmart Model X-100TM.

    • Yuichi Tanaka, Manzo Suzuki, Kenji Yoshitani, Atsuhiro Sakamoto, and Hiroyasu Bito.
    • Department of Anesthesiology, Musashikosugi Hospital, Nippon Medical School, 1-396 Kosugi-cho, Nakahara-ku, Kawasaki, Kanagawa, 211-8533, Japan.
    • J Clin Monit Comput. 2021 Oct 1; 35 (5): 1063-1068.

    AbstractThe Sensmart Model X-100 (Nonin Medical Inc, Plymouth, MN, USA) is a relatively new device that possesses two sets of emitters and detectors and uses near infrared spectroscopy (NIRS) to measure regional cerebral oxygen saturation (rSO2). The value of rSO2 obtained by other NIRS devices is affected by physiological and anatomical variables such as hemoglobin concentration, area of cerebrospinal fluid (CSF) layer and skull thickness. The effects of these variables have not yet been determined in measurement of rSO2 by Sensmart Model X-100. We examined the effects of area of CSF, hemoglobin concentration, and skull thickness on the values of rSO2 measured by Sensmart Model X-100 and tissue oxygen index (TOI) measured by NIRO-200NX (Hamamatsu Photonix, Hamamatsu, Japan). Forty neurosurgical, cardiac and vascular surgical patients who underwent preoperative computed tomographic (CT) scan of the brain were enrolled in this study. Regional cerebral oxygen saturation (rSO2) at the forehead was measured sequentially by NIRO-200NX and by Sensmart Model X-100. Simultaneously, mean arterial pressure, hemoglobin concentration, and partial pressure of carbon dioxide in arterial blood (PaCO2) were measured. To evaluate the effects of anatomical factors on rSO2, we measured skull thickness and area of CSF layer using CT images of the brain. Multiple regression analysis was used to examine the relationships between the rSO2 values and anatomical and physiological factors. The area of the CSF layer and hemoglobin concentration had significant associations with rSO2 measured by the Sensmart Model X-100, whereas none of the studied variables was significantly associated with TOI. The measurement of rSO2 by Sensmart Model X-100 is not affected by the skull thickness of patients. Area of the CSF layer and hemoglobin concentration may be the main biases in measurement of rSO2 by Sensmart Model X-100.© 2020. Springer Nature B.V.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.