• Spine · Nov 2020

    Frameless Patient Tracking with Adhesive Optical Skin Markers for Augmented Reality Surgical Navigation in Spine Surgery.

    • Gustav Burström, Rami Nachabe, Robert Homan, Jurgen Hoppenbrouwers, Ronald Holthuizen, Oscar Persson, Erik Edström, and Adrian Elmi-Terander.
    • Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.
    • Spine. 2020 Nov 15; 45 (22): 1598-1604.

    Study DesignObservational study.ObjectiveThe aim of this study was to evaluate the accuracy of a new frameless reference marker system for patient tracking by analyzing the effect of vertebral position within the surgical field.Summary Of Background DataMost modern navigation systems for spine surgery rely on a dynamic reference frame attached to a vertebra for tracking the patient. This solution has the drawback of being bulky and obstructing the surgical field, while requiring that the dynamic reference frame is moved between vertebras to maintain accuracy.MethodsAn augmented reality surgical navigation (ARSN) system with intraoperative cone beam computed tomography (CBCT) capability was installed in a hybrid operating room. The ARSN system used input from four video cameras for tracking adhesive skin markers placed around the surgical field. The frameless reference marker system was evaluated first in four human cadavers, and then in 20 patients undergoing navigated spine surgery. In each CBCT, the impact of vertebral position in the surgical field on technical accuracy was analyzed. The technical accuracy of the inserted pedicle devices was determined by measuring the distance between the planned position and the placed pedicle device, at the bone entry point.ResultsThe overall mean technical accuracy was 1.65 ± 1.24 mm at the bone entry point (n = 366). There was no statistically significant difference in technical accuracy between levels within CBCTs (P ≥ 0.12 for all comparisons). Linear regressions showed that null- to negligible parts of the effect on technical accuracy could be explained by the number of absolute levels away from the index vertebrae (r ≤ 0.007 for all, β ≤ 0.071 for all).ConclusionThe frameless reference marker system based on adhesive skin markers is unobtrusive and affords the ARSN system a high accuracy throughout the navigated surgical field, independent of vertebral position.Level Of Evidence3.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…