J. Thorac. Cardiovasc. Surg. · Mar 2011
Comparative StudyIntraoperative device closure of atrial septal defects with inferior vena cava rim deficiency: a safe alternative to surgical repair.
- Qiang Chen, Liang-Wan Chen, Hua Cao, Gui-Can Zhang, Dao-Zhong Chen, and Hui Zhang.
- Department of Cardiovascular Surgery, Union Hospital, Fujian Medical University, Fuzhou, People's Republic of China.
- J. Thorac. Cardiovasc. Surg. 2011 Mar 1; 141 (3): 631-6.
ObjectiveOur objective was to evaluate the safety and feasibility of intraoperative device closure of atrial septal defects with inferior vena cava rim deficiency.MethodsFrom January 2005 to December 2008, we enrolled 65 patients who had a secundum atrial septal defect with inferior vena cava rim deficiency closure in our institution. Patients were divided into 2 groups: 35 patients in group I underwent intraoperative device closure with a right lateral minithoracotomy and 30 in group II underwent open cardiac repair with a right lateral thoracotomy and cardiopulmonary bypass. Intraoperative device closure involved a minimal intercostal incision that was performed after full evaluation of the atrial septal defect by transthoracic echocardiography and the insertion of the device through the delivery sheath to occlude the atrial septal defect.ResultsThe procedure was successful in all patients. In group I, the diameter of the atrial septal defect ranged from 30 to 44 mm (mean, 35.3 ± 3.9 mm), and the size of the implanted occluder ranged from 34 to 48 mm (mean, 40 ± 2.1 mm). The total occlusion rate was 82.9% immediately after the operation, 97.1% at 3 months, and 100% at 12 and 24 months of follow-up. In group II, all patients had successful closure. A follow-up period of 12 to 24 months was obtained in both groups. During the follow-up, there was no recurrence, thrombosis, or device failure. In our comparative studies, group II had significantly longer operative time, intensive care unit stay, and hospital stay than group I (P < .001). The cost of group I was less than that of group II (20,450.9 ± 840.8 RMB vs 25,884.9 ± 701.8; P < .001).ConclusionsIntraoperative device closure of atrial septal defects with inferior vena cava rim deficiency is a safe and feasible technique. It has the advantages of cost savings, cosmetic results, and less trauma than surgical closure. Early and midterm results are encouraging.Crown Copyright © 2011. Published by Mosby, Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.