Pulse rate as an alternative, real-time feedback indicator for chest compression rate: a porcine model of cardiac arrest.
- Yangyang Fu, Lu Yin, Samuel Seery, Jiayuan Dai, Huadong Zhu, Kui Jin, Yi Li, Shanshan Yu, Lili Zhang, Jun Xu, and Xuezhong Yu.
- Department of Emergency, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No.1 Shuaifuyuan, Wangfujing, Dongcheng District, Beijing, 100730, China.
- J Clin Monit Comput. 2021 Oct 1; 35 (5): 1159-1167.
AbstractFeedback indicators can improve chest compression quality during cardiopulmonary resuscitation (CPR). However, the application of feedback indicators in the clinic practice is rare. Pulse oximetry has been widely used and reported to correlate spontaneous circulation restoration during CPR. However, it is unclear if pulse oximetry can monitor the quality of chest compression. We hypothesized that pulse rate monitored by pulse oximetry can be used as a feedback indicator of the chest compression rate during CPR in a porcine model of cardiac arrest. Seven domestic male pigs (30-35 kg) were utilized in this study. Eighteen intermittent chest compression periods of 2 min were performed on each animal. Chest compression and pulse oximetry plethysmographic waveforms were recorded simultaneously. Chest compression and pulse rates were calculated based on both waveforms. Compression interruption and synchronous pulse interruption times were also measured. Agreement was analyzed between pulse rates and synchronous chest compression rates, as well as between compression interruption times and synchronous pulse interruption times. A total of 126 compression periods of 2 min were performed on seven animals. Interclass correlation coefficients and Bland-Altman analysis revealed reliable agreement between pulse rates and synchronous chest compression rates. Similarly, compression interruption and synchronous pulse interruption times obtained also showed high agreement. Pulse rate can be used as an alternative indicator of chest compression rate during CPR in a porcine model of cardiac arrest. Pulse interruption time also can be used to reflect compression interruption time precisely in this model.© 2020. Springer Nature B.V.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.