    BackgroundThe subthalamic nucleus (STN) is an important target during deep brain stimulation (DBS). Accurate lead placement is integral to achieving satisfactory clinical outcomes; however, the STN remains a structure whose visualization is highly variable with borders often difficult to define. We aimed to develop an objective method of evaluating the visibility of the STN on preoperative magnetic resonance imaging (MRI) to standardize future comparative assessments between imaging protocols and patient-specific parameters.MethodsAn imaging study of 64 prospectively collected patients undergoing bilateral DBS of the STN for various movement disorders was performed with institutional approval. MRI scans were acquired using a uniform protocol involving general anesthesia, cranial fixation in a Leksell stereotactic frame, and long acquisition times using a 3T MRI scanner. The images were analyzed using the iPlan Stereotaxy, version 2.6, workstation. High-resolution T2-weighted axial sections were evaluated, and the voxel values in the region of the presumed posterior border of the STN (as defined by the operating neurosurgeon) were obtained. A 4-parameter logistic symmetrical sigmoid curve was used to map the voxel values as they progressed from within to outside the region of the STN border. The inflection point and Hill coefficient of this symmetrical curve was calculated to provide objective information on the location and clarity of the STN border, respectively. These findings were compared with the surgeon's judgment of the STN border. To demonstrate the use of the sigmoid curve, the patients' head volumes were also calculated and evaluated to assess whether larger head volumes adversely affected STN visibility.ResultsThe symmetrical sigmoid curve model provided objective information on the visibility of the STN on T2-weighted MRI scans and could be generated in 86% of the patients. The other 14% of patients had MRI scans that generated linear graphs, indicating the poorest scoring for STN image quality. No correlation between head volume and STN visibility was identified.ConclusionsOur proposed statistical model allows for standardized examination of the visibility of the STN border for DBS and has potential for both clinical and academic applications.Copyright © 2020 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.