Case Reports
Placement of a Double-Lumen Endotracheal Tube Using a Combined Bronchoscopy and Fluoroscopy Technique: A Case Report.
- Aaron R Muncey, Jennifer Sweeney, and Osama Hafez.
- From the Department of Anesthesiology, H. Lee Moffitt Cancer Center, Tampa, Florida.
- A A Pract. 2020 Apr 1; 14 (6): e01198.
AbstractBronchial artery embolization (BAE) is a well-established intervention for hemoptysis that requires airway management by a trained anesthesiologist. The use of fluoroscopic guidance for positioning a double-lumen endotracheal tube (DLT) has been described in previous studies. The case presented illustrates a combined fluoroscopic- and bronchoscopic-guided approach for positioning a DLT in a patient with active pulmonary hemorrhage causing obstruction of views on bronchoscopy. This combined technique proved valuable in a situation marked by high clinical urgency.