-
J Clin Monit Comput · Oct 2021
Technical considerations when using the EEG export of the SEDLine Root device.
- Falk von Dincklage, Carlo Jurth, Gerhard Schneider, S GarcíaPaulPDepartment of Anesthesiology, Neuroanesthesia Division, Columbia University Medical Center, New York Presbyterian Hospital, New York, USA., and Matthias Kreuzer.
- Klinik für Anästhesiologie m.S. operative Intensivmedizin (CCM/CVK), Charité - Universitätsmedizin Berlin, Berlin, Germany.
- J Clin Monit Comput. 2021 Oct 1; 35 (5): 1047-1054.
AbstractElectroencephalographic (EEG) patient monitoring during general anesthesia can help to assess the real-time neurophysiology of unconscious states. Some monitoring systems like the SEDLine Root allow export of the EEG to be used for retrospective analysis. We show that changes made to the SEDLine display during recording affected the recorded EEG. These changes can strongly impact retrospective analysis of EEG signals. Real-time changes of the feed speed in the SEDLine Root device display modifies the sampling rate of the exported EEG. We used a patient as well as a simulated EEG recording to highlight the effects of the display settings on the extracted EEG. Therefore, we changed EEG feed and amplitude resolution on the display in a systematic manner. To visualize the effects of these changes, we present raw EEG segments and the density spectral array of the recording. Changing the display's amplitude resolution affects the amplitudes. If the amplitude resolution is too fine, the exported EEG contains clipped amplitudes. If the resolution is too coarse, the EEG resolution becomes too low leading to a low-quality signal making frequency analysis impossible. The proportion of clipped or zero-line data caused by the amplitude setting was > 60% in our sedated patient. Changing the display settings results in undocumented changes in EEG amplitude, sampling rate, and signal quality. The occult nature of these changes could make the analysis of data sets difficult if not invalid. We strongly suggest researchers adequately define and keep the EEG display settings to export good quality EEG and to ensure comparability among patients.© 2020. The Author(s).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.