-
Comparative Study
Area under the expiratory flow-volume curve (AEX): actual versus approximated values.
- Octavian C Ioachimescu and James K Stoller.
- Medicine - Pulmonary, Allergy, Critical Care and Sleep Medicine, Atlanta VAMC, Emory University, School of Medicine, Decatur, Georgia, USA.
- J. Investig. Med. 2020 Feb 1; 68 (2): 403-411.
AbstractPrevious work has shown that area under the expiratory flow-volume curve (AEX) performs well in diagnosing and stratifying respiratory physiologic impairment, thereby lessening the need to measure lung volumes. Extending this prior work, the current study assesses the accuracy and utility of several geometric approximations of AEX based on standard instantaneous flows. These approximations can be used in spirometry interpretation when actual AEX measurements are not available. We analysed 15 308 spirometry tests performed on subjects who underwent same-day lung volume assessments in the Pulmonary Function Laboratory. Diagnostic performance of four AEX approximations (AEX1-4) was compared with that of actual AEX. All four computations included forced vital capacity (FVC) and various instantaneous flows: AEX1 was derived from peak expiratoryflow (PEF); AEX2 from PEF and forced expiratoryflow at 50% FVC (FEF50); AEX3 from FVC, PEF, FEF at 25% FVC (FEF25) and at 75% FVC (FEF75), while AEX4 was computed from all four flows, PEF, FEF25, FEF50 and FEF75 Mean AEX, AEX1, AEX2, AEX3 and AEX4 were 6.6, 8.3, 6.7, 6.3 and 6.1 L2/s, respectively. All four approximations had strong correlations with AEX, that is, 0.95-0.99. Differences were the smallest for AEX-AEX4, with a mean of 0.52 (95% CI 0.51 to 0.54) and a SD of 0.75 (95% CI 0.74 to 0.76) L2/s. In the absence of AEX and in addition to the usual spirometric variables used for assessing functional impairments, parameters such as AEX4 can provide reasonable approximations of AEX and become useful new tools in future interpretative strategies.© American Federation for Medical Research 2020. No commercial re-use. See rights and permissions. Published by BMJ.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.