-
Randomized Controlled Trial Multicenter Study Comparative Study
Cost-Effectiveness of Self-Expandable Transcatheter Aortic Valves in Intermediate-Risk Patients.
- Derrick Y Tam, Avery Hughes, Harindra C Wijeysundera, and Stephen E Fremes.
- Division of Cardiac Surgery, Department of Surgery, Schulich Heart Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada; Institute of Health Policy, Management and Evaluation, University of Toronto, Toronto, Ontario, Canada.
- Ann. Thorac. Surg. 2018 Sep 1; 106 (3): 676-683.
BackgroundA recent clinical trial showed that self-expandable transcatheter aortic valve replacement (TAVR) was non-inferior to surgical aortic valve replacement (SAVR). However, the cost-effectiveness of self-expandable TAVR in the intermediate-risk population remains unknown.MethodsA cost-utility analysis from the Canadian health care system payer's perspective was undertaken to compare self-expandable TAVR with SAVR. A fully probabilistic Markov model over the patient's lifetime was constructed to estimate differences in costs (2016 Canadian dollars) and effectiveness (quality-adjusted life-years [QALYs]), discounted at 1.5% per annum. Incremental cost-effectiveness ratios (ICERs) were calculated. Efficacy inputs were obtained from the Surgical Replacement and Transcatheter Aortic Valve Implantation trial, and costs were primarily obtained from the Canadian Institute of Health Information. Probabilistic analysis (PA) and one-way deterministic sensitivity analyses were conducted around key point estimates to address uncertainty.ResultsIn the base case analysis, with discounting, the total lifetime costs (mean ± standard deviation) in the TAVR and SAVR arms were $44,299 ± $7,260 and $32,994 ± $13,434, respectively, whereas total effectiveness values were 6.42 ± 1.33 QALYs and 6.28 ± 1.32 QALYs, respectively. This yielded an incremental cost of $11,305 and incremental effectiveness of 0.15 QALYs when TAVR was compared with SAVR for an ICER of $76,736/QALY. In the PA, there was moderate uncertainty, with 52.8% and 57.2% of simulations less than willingness-to-pay thresholds of $50,000 and $100,000, respectively. In the sensitivity analysis, when the cost of TAVR valve system was priced at $17,397 (base case $22,000 Canadian dollars), TAVR was found to be cost-effective at a willingness-to-pay threshold of $50,000/QALY.ConclusionsSelf-expandable TAVR was found to be cost-effective; however, there was moderate uncertainty, reflecting the non-inferiority nature of the data.Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.