-
J Am Soc Echocardiogr · Oct 2014
Comparative StudyAssessment of left ventricular volumes with echocardiography and cardiac magnetic resonance imaging: real-life evaluation of standard versus new semiautomatic methods.
- Matthias Aurich, Florian André, Marius Keller, Sebastian Greiner, Alexander Hess, Sebastian J Buss, Hugo A Katus, and Derliz Mereles.
- Department of Internal Medicine III, Cardiology, Angiology and Pneumology, University of Heidelberg, Heidelberg, Germany. Electronic address: matthias.aurich@med.uni-heidelberg.de.
- J Am Soc Echocardiogr. 2014 Oct 1; 27 (10): 1017-24.
BackgroundRoutine quantitative assessment of left ventricular (LV) volumes with echocardiography is hindered by time-consuming methods requiring a manual trace of the LV cavity from two apical two-dimensional planes. Thus, the aim of this study was to evaluate faster new semiautomatic echocardiographic methods that could represent a feasible alternative for the assessment of LV volumes and ejection fraction (EF) in clinical practice.MethodsTwo semiautomatic methods, the automated EF (Auto-EF) for two-dimensional echocardiography and the 4D Auto LVQ tool for three-dimensional echocardiography (3DE), were compared with the biplane modified Simpson's method and cardiac magnetic resonance (CMR) imaging in 47 patients. To evaluate the accuracy of volumetry, additional in vitro measurements using water-filled latex balloons were performed with both modalities.ResultsResults of balloon volumetry by echocardiography and CMR measurements were in good agreement with real balloon volumes. The mean LV EF was 45 ± 11% by Auto-EF, 45 ± 11% by 3DE, 48 ± 11% by Simpson's method, and 54 ± 12% by CMR. Linear regression and Bland-Altman analyses showed good associations for semiautomatic methods with Simpson's method (Auto-EF, r = 0.85, bias = 3%, limits of agreement [LOA] = 12%; 3DE, r = 0.79, bias = 3%, LOA = 14%), as well as with CMR (Auto-EF, r = 0.74, bias = 9%, LOA = 17%; 3DE, r = 0.73, bias = 9%, LOA = 17%). Intra- and interobserver variability were 6% and 12% with Auto-EF and 8% and 11% with 3DE, respectively.ConclusionsGood correlations between semiautomatic echocardiographic parameters for assessment of LV volumes and EF could be observed when compared with Simpson's method or CMR. However, intertechnique agreement analysis of absolute LV volumes revealed considerable differences, with significant underestimation of volumes and EF with respect to CMR.Copyright © 2014 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.