    ObjectivesInsufficient distance between membranous septum (MS) length and implant depth (ID) may aggravate mechanical compression of the conduction tissue by transcatheter aortic valve replacement (TAVR) prosthesis. We investigated the implication of MS length measured in the coronal view (coronal MS length) compared with infra-annular MS length from stretched vessel image to predict conduction disturbances following TAVR with CoreValve/Evolut R valves (Medtronic, Minneapolis, Minn).MethodsAmong 195 consecutive patients undergoing TAVR with CoreValve/Evolut R valves, we evaluated coronal, infra-annular MS lengths and ID, as well as MS length minus ID (ΔMSID) using pre-TAVR computed tomography and postprocedural angiography.ResultsWithin 30 days, 6 (3.1%) required permanent pacemaker implantation and 31 (16.4%) developed left bundle branch block. When taking into account pre- and postprocedural parameters, multivariable logistic regression analysis revealed either coronal ΔMSID (odds ratio, 0.80; 95% confidence interval, 0.72-0.89; P < .001; cutoff point, 3.2 mm) or infra-annular ΔMSID (odds ratio, 0.84; 95% confidence interval, 0.76-0.92; P < .001; cutoff point, -0.2 mm) emerged as the only modifiable predictor of conduction disturbances. The area under the curve of coronal ΔMSID and infra-annular ΔMSID for predicting the occurrence of conduction disturbances were comparable (0.717 in coronal ΔMSID vs 0.708 in infra-annular ΔMSID; P = .761), but more patients could be guided by coronal MS length than infra-annular MS length (95.9% vs 87.2%; P = .002).ConclusionsPreprocedural assessment of MS length should be routinely adopted to determine the optimal ID to mitigate individual patient susceptibility to conduction disturbances after TAVR with self-expanding valves.Copyright © 2020 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.