• Emerg Med J · Feb 2021

    Nurse practitioner administered point-of-care ultrasound compared with X-ray for children with clinically non-angulated distal forearm fractures in the ED: a diagnostic study.

    • Peter J Snelling, Philip Jones, Gerben Keijzers, David Bade, David W Herd, and Robert S Ware.
    • School of Medicine, Griffith University Faculty of Health, Southport, Queensland, Australia peter.snelling@health.qld.gov.au.
    • Emerg Med J. 2021 Feb 1; 38 (2): 139-145.

    BackgroundPaediatric distal forearm fractures are a common ED presentation. They can be diagnosed with point-of-care ultrasound (POCUS) as an alternative to X-rays. Given that ED nurse practitioners (NPs) are relied on for the diagnosis of paediatric fractures, it is important to describe the diagnostic accuracy of NP-conducted POCUS versus X-ray.MethodsThis prospective diagnostic study was conducted in a tertiary paediatric hospital in Queensland, Australia, between February 2018 and April 2019. Participants were children aged 4-16 years with a clinically non-angulated, suspected distal forearm fracture. Diagnosis from 6-view NP-administered POCUS of the distal radius and ulna was compared against the reference standard of 2-view X-ray. Each patient received both imaging modalities. Overall forearm diagnosis was classified as 'no', 'buckle' or 'other' fracture for both modalities. The primary outcome was diagnostic accuracy for 'any' fracture ('buckle' and 'other' fractures combined). Secondary outcomes included diagnostic accuracy for 'other' fractures versus 'buckle' and 'no' fractures combined, and pain, imaging duration and preference for modality.ResultsOf 204 recruited patients, 129 had X-ray-diagnosed forearm fractures. The sensitivity and specificity for NP-administered POCUS were 94.6% (95% CI 89.2% to 97.3%) and 85.3% (95% CI 75.6% to 91.6%), respectively. 'Other' fractures (mostly cortical breach fractures), when compared with 'buckle'/ 'no' fractures, had sensitivity 81.0% (95% CI 69.1% to 89.1%) and specificity 95.9% (95% CI 91.3% to 98.1%). Pain and imaging duration were clinically similar between modalities. There was a preference for POCUS by patients, parents and NPs.ConclusionsNP-administered POCUS had clinically acceptable diagnostic accuracy for paediatric patients presenting with non-angulated distal forearm injuries. This included good sensitivity for diagnosis of 'any' fracture and good specificity for diagnosis of cortical breach fractures alone. Given the preference for POCUS, and the lack of difference in pain and duration between modalities, future research should consider functional outcomes comparing POCUS with X-ray in this population in a randomised controlled trial.© Author(s) (or their employer(s)) 2021. No commercial re-use. See rights and permissions. Published by BMJ.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…