Comparative Study
A Direct Comparison of Self-Expandable Portico Versus Balloon-Expandable Sapien 3 Devices for Transcatheter Aortic Valve Replacement: A Case-Matched Cohort Study.
- Silvia Mas-Peiro, Philipp Christian Seppelt, Helge Weiler, Gina-Lisa Mohr, Nestoras Papadopoulos, Thomas Walther, Andreas M Zeiher, Stephan Fichtlscherer, and Mariuca Vasa-Nicotera.
- Department of Cardiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany. silvia.mas@kgu.de.
- J Invasive Cardiol. 2019 Jul 1; 31 (7): E199-E204.
ObjectivesPairwise comparisons of clinical and hemodynamic outcomes with new transcatheter aortic valve replacement (TAVR) prostheses are needed to help interventionists select the most appropriate device. The self-expandable Portico valve (Abbott Vascular) was compared with the balloon-expandable Sapien 3 valve (Edwards Lifesciences) at a high-volume center in a real-world setting.MethodsAll patients undergoing TAVR with a new-generation device from March 2015 to September 2017 at a single center were included. Baseline, peri-interventional, and prospective 30-day follow-up data were obtained. A nearest-neighbor propensity-score matching procedure (2:1) was used, based on age, STS score, EuroScore II, New York Heart Association (NYHA) status, and sex. Primary endpoint was 30-day all-cause mortality. Secondary endpoints included procedural results, complications according to Valve Academic Research Consortium (VARC)-2 criteria, and echocardiographic findings.ResultsA total of 177 out of 273 patients were matched (104 Portico valves and 73 Sapien 3 valves). Procedural success rates were 99.0% vs 98.6%, respectively; P=NS). Contrast dye use (160 mL for Portico vs 120 mL for Sapien 3; P<.001) and fluoroscopy time (19.0 min for Portico vs 15.5 min for Sapien 3; P=.048) were significantly lower with the Sapien 3 device. Thirty-day mortality rate was 5.8% for the Portico group vs 4.1% for the Sapien 3 group (P=.74). Complication rates were similar between Portico and Sapien 3 groups: stroke (2.9% vs 4.1%, respectively; P=.31), major bleeding (3.8% vs 5.5%, respectively; P=.51), major vascular complications (5.8% vs 5.5%, respectively; P=.99), and pacemaker implantation (21.9% vs 17.5%, respectively; P=.55). A more-than-mild paravalvular leak was observed in 8.2% vs 4.5%, respectively (P=NS).ConclusionsShort-term clinical and hemodynamic outcomes were similar with Portico and Sapien 3 prostheses; no statistically significant differences were observed in mortality and major complication rates. An individually tailored prosthesis choice is suggested.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.