• Anesthesia and analgesia · Sep 2002

    Clinical Trial

    The use of a uniquely designed anesthetic scavenging hood to reduce operating room anesthetic gas contamination during general anesthesia.

    • Moeen K Panni and Stephen B Corn.
    • Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115, USA.
    • Anesth. Analg. 2002 Sep 1; 95 (3): 656-60, table of contents.

    UnlabelledNumerous studies have suggested that chronic exposure to trace levels of anesthetic gas is harmful to operating room (OR) personnel. In the delivery of pediatric general anesthesia, an uncuffed endotracheal tube (ETT) is normally used which can result in considerable volatile anesthetic and nitrous oxide contamination of the OR. In this report, we present a method to reduce exposure to these anesthetic gases by means of an anesthetic scavenging hood (ASH). The ASH was used on six pediatric patients undergoing general endotracheal anesthesia via an uncuffed ETT. Measurements of all ambient gas levels were made 6 in. horizontally from the patient's ear and 6 in. from the table surface. The application of the vacuum source to the ASH resulted in a very significant (P < 0.01, paired t-test) decrease in levels of ambient anesthetic gas, with no measurable change in ventilatory variables or changes in body temperature (P > 0.05, paired t-test). Discontinuation of the vacuum force to the ASH resulted in a marked increase in ambient levels of anesthetic gas. We conclude that the ASH is extremely effective in reducing waste anesthetic gas associated with anesthesia administered via an uncuffed ETT. The ASH may be a valuable and cost-effective addition in the OR for both reducing ambient anesthetic waste gas levels and conserving patient heat.ImplicationsChronic exposure to trace levels of anesthetic gas is harmful to operating room personnel, especially in the delivery of pediatric general anesthesia via an uncuffed endotracheal tube. The anesthetic scavenging hood is a cost-effective and efficient method to reduce these waste anesthetic gases, and it offers patient heat conservation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…