    Evaluation of a simple, potentially individual device for exhaled breath temperature measurement.

    • Todor A Popov, Stefan Dunev, Tanya Z Kralimarkova, Steliana Kraeva, and Lawrence M DuBuske.
    • Clinic of Allergy and Asthma, Medical University Sofia, 1, Sv. Georgi Sofiyski Street, BG 1431, Sofia, Bulgaria. tedpop@rtb-mu.com
    • Respir Med. 2007 Oct 1; 101 (10): 2044-50.

    RationaleInflammation is a universal pathological reaction and is characterized among other things by increased heat production. The question stays whether the contribution of the inflamed lung tissues to the overall exhaled breath temperature (EBT) can be reliably detected and used in everyday clinical practice.MethodsWe have designed a simple device for assessment of EBT and explored its performance under standard indoor conditions. We made our measurements in the morning hours, documenting the ambient conditions (room temperature, humidity, atmospheric pressure), and physiological characteristics of the tested subjects (heart rate, blood pressure, otic and axillary temperature). We assessed its day-to-day reproducibility in 17 healthy volunteers and its ability to discriminate between the same subjects without respiratory disease and uncontrolled asthmatics (n=14). We also compared the EBT of the 14 asthmatics before and after anti-inflammatory treatment.ResultsNo association was found between EBT and any of the ambient conditions: room temperature, atmospheric pressure and humidity. While otic and axillary temperatures, which were measured in parallel, maintained high correlation between each other (Spearman's rho=0.71, p<0.01), EBT did not show meaningful association with any of them. The EBT (degrees C) of asthmatics (median 35.45, range 34.12-36.09) was higher than that of controls (34.84, 32.29-35.84), (p=0.009, Mann-Whitney U test). Anti-inflammatory treatment brought down the EBT of the asthmatics (34.78, 33.23-36.06), (p=0.001, Wilcoxon Signed Ranks test), while significantly improving their spirometry too.ConclusionsMeasurements of EBT with the device we constructed are not significantly influenced by changes within the accepted range of a standard indoor environment. EBT represents a different characteristic of the human organism than otic and axillary temperatures. EBT is increased in uncontrolled asthmatics and decreases under anti-inflammatory treatment.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…