ObjectivesTo construct reference ranges for stroke volume, cardiac output and systemic vascular resistance (SVR) in normal pregnancy for the NICOM® device, and to explore associations between maternal characteristics and these hemodynamic variables.MethodsThis was a prospective cohort study of healthy singleton pregnancies between 10 and 40 weeks' gestation attending a tertiary referral hospital between September 2012 and May 2018. Measurements of stroke volume, cardiac output and SVR were obtained throughout pregnancy using NICOM, a non-invasive device based on bioreactance technology. NICOM device-specific reference ranges were created with respect to gestational age and maternal characteristics. Once the distribution of the data had been determined with respect to the gestational age, patient characteristics were added to the model to test whether they provided a significant improvement in prediction of the median value. The effect was assessed of maternal weight, height, smoking status, conception using assisted reproductive technology, nulliparity and ethnicity.ResultsWe included 411 women in this study. The relationships between cardiac variables and gestational age observed in the NICOM-specific reference ranges are consistent with previous findings, with increasing cardiac output values until around 35 weeks and a decrease thereafter until term, and decreasing SVR until around 36 weeks, followed by an increase towards 40 weeks. Stroke volume showed a small linear increase across gestation with lower variability in observations close to term. Maternal weight, height and age were associated with cardiac output (all P < 0.05) and SVR (all P < 0.01), whilst maternal weight and height were associated with stroke volume (both P < 0.001). Ethnicity was significantly associated with stroke volume (P = 0.001) but not with cardiac output or SVR.ConclusionsThis study presents device-specific reference ranges for stroke volume, cardiac output and SVR for the NICOM device in healthy pregnancy and describes the maternal characteristics that are associated with the values of these hemodynamic measurements. Studies using NICOM in pregnancy can use these ranges in order to evaluate observations relative to those expected in uncomplicated pregnancy conditional on maternal characteristics. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.