• Pediatric emergency care · Jan 2022

    Which Device Is Favorable for Intubation Attempts of Pediatric Residents on Four Different Pediatric Airway Simulations?

    • Anıl Er, Aykut Çağlar, Hale Çitlenbik, Fatma Akgül, Emel Ulusoy, Hale Ören, Durgül Yιlmaz, and Murat Duman.
    • From the Division of Pediatric Emergency Medicine, Department of Pediatrics.
    • Pediatr Emerg Care. 2022 Jan 1; 38 (1): e272e277e272-e277.

    ObjectivesEndotracheal intubation is an essential skill for the pediatric airway management. Although direct laryngoscopy (DL) is the standard method, several videolaryngoscopes (VLs) have been recently enhanced as an alternative especially for difficult intubations. We aimed to compare McGrath MAC (McG) and Storz C-MAC PM (ST) VLs with DL in terms of intubation success rate, time to intubation (TTI), and duration of obtaining glottis view of intubation attempts performed by pediatric residents on different pediatric airway manikins.MethodsThe pediatric residents with no experience in videolaryngoscopy were included. After a brief demonstration, intubation attempts with 3 randomly handled different devices with 6 different blades were performed on a child manikin, an infant manikin, a Pierre-Robin sequence infant manikin, and a child manikin with cervical immobilization sequentially.ResultsFifty pediatric residents were enrolled. The attempts of DL on child manikin and attempts of all devices on child with cervical immobilization simulation were completely successful. For the attempts on both infant manikin and Pierre-Robin sequence infant manikin, the success rate of McG was significantly lower than ST and DL (P = 0.011 and P = 0.001). In the child manikin, McG and ST had prolonged TTI compared with DL (P = 0.016 and P = 0.001). For the child with cervical immobilization simulation, TTI of DL was significantly shorter than McG and ST (P = 0.011 and P = 0.001). Time to intubation of McG was significantly longer than DL and ST for the attempts on both 2 infant manikins. The rate of Cormack-Lehane grade I glottis view was similar for the attempts on both 2 child airway simulations. For infant manikin and Pierre-Robin sequence infant simulation, the rate of Cormack-Lehane grade I of ST was higher than attempts of DL and McG.ConclusionsThe attempts of pediatric residents on infant normal airway and Pierre-Robin sequence infant airway simulations resulted with enhanced glottis view by the utilization of Storz C-MAC PM, but both 2 VLs did not provide the improvement of intubation success rate and TTI compared with DL on these 4 different pediatric manikins. Further clinical studies of different VLs in different clinical courses are required for a reliable utilization in children.Copyright © 2020 Wolters Kluwer Health, Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…