• Chest · Apr 2021

    Randomized Controlled Trial

    Randomized Controlled Trial of a Novel Communication Device Assessed during Noninvasive Ventilation Therapy.

    • WongAn-Kwok IanAIEmory University Division of Pulmonary, Allergy, Critical Care, and Sleep Medicine; Emory University Department of Medicine. Electronic address: med@aiwong.com., Patricia C Cheung, James Zhang, George Cotsonis, Michael Kutner, Peter C Gay, and Nancy A Collop.
    • Emory University Division of Pulmonary, Allergy, Critical Care, and Sleep Medicine; Emory University Department of Medicine. Electronic address: med@aiwong.com.
    • Chest. 2021 Apr 1; 159 (4): 1531-1539.

    BackgroundNoninvasive ventilation (NIV), a form of positive airway pressure (PAP) therapy, is the standard of care for various forms of acute respiratory failure (ARF). Communication impairment is a side effect of NIV, impedes patient care, contributes to distress and intolerance, and potentially increases intubation rates. This study aimed to evaluate communication impairment during CPAP therapy and demonstrate communication device improvement with a standardized protocol.Research QuestionHow does an oronasal mask affect communication intelligibility? How does use of an NIV communication device change this communication intelligibility?Study Design And MethodsA single-center randomized controlled trial (36 outpatients with OSA on CPAP therapy) assessed exposure to CPAP 10 cm H2O and PAP communication devices (SPEAX, Ataia Medical). Communication impairment was evaluated by reading selected words and sentences for partners to record and were tabulated as %words correct. Each outpatient-partner pair performed three assessments: (1) baseline (conversing normally), (2) mask baseline (conversing with PAP), and (3) randomized to functioning device (conversing with PAP and device) or sham device. After each stage, both outpatients and partners completed Likert surveys regarding perceived intelligibility and comfort.ResultsWhile conversing with PAP, word and sentence intelligibility decreased relatively by 52% (87% vs 41%) and relatively by 57% (94% vs 40%), respectively, compared with normal conversation. Word and sentence intelligibility in the intervention arm increased relatively by 75% (35% vs 61%; P < .001) and by 126% (33% vs 76%; P < .001) higher than the control arm, respectively. The device improved outpatient-perceived PAP comfort relatively by 233% (15% vs 50%, P = .042) and partner-perceived comfort by relatively 245% (20% vs 69%, P = .0074).InterpretationUse of this PAP communication device significantly improves both intelligibility and comfort. This is one of the first studies quantifying communication impairment during PAP delivery.Trial RegistryClinicalTrials.gov; No.: NCT03795753; URL: www.clinicaltrials.gov.Copyright © 2020 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.