-
- U Matern, P Waller, C Giebmeyer, K D Rückauer, and E H Farthmann.
- Department of General Surgery, University-Hospital of Freiburg, Germany. matern@ch11.uk.uni-freiburg.de
- JSLS. 2001 Jan 1; 5 (1): 7-12.
Background And ObjectivesIn the last few years many new instruments and devices have been developed and introduced into the operating room (OR). A debate has been ongoing about the optimal ergonomic posture for the operating staff. From practical experience, we have learned that the operating tables cannot be adjusted adequately to allow surgeons of different stature to maintain a comfortable posture. The goal of this study was to establish the most ergonomic table height for the particular physique of the surgeon and the different types of laparoscopic instrument handles that he or she uses.MethodsIn a simulated model, two probands of different stature (50th [BS 50] and 95th [BS 95] percentile) used laparoscopic instruments with four different handle designs (shank, pistol, axial, and rod). The instruments were inserted into a board in three different angles ([IA] = 20 degrees, 30 degrees, 40 degrees). Additionally the elbow angles (EA) of the volunteers were fixed to either 90 degrees or 120 degrees. For every variable (size of surgeon and his or her elbow angle, design of handle, insertion angle of the instrument) the height of the board, as a parameter for the level of the abdominal wall of a patient with pneumoperitioneum, was measured from the floor.ResultsAll parameters had an effect on the optimal operating table height. The lowest required operating table level was 30 cm, the highest was 60.5 cm. In laparoscopic surgery-long shafted instruments and patients with pneumoperitoneum-the tabletops are too high for over 95% of all surgeons. As skin incision and wound suture are performed the conventional way, the operating tabletop must be adjustable up to the common height of 122 cm. The maximal difference between the optimal heights of the OR-table for one volunteer using two different handles with different insertion angles of the instruments (BS 95, EA 90 degrees, IA 20 degrees, rod handle to BS 50, EA 120 degrees, IA 40 degrees, axial handle) was about 27 cm.ConclusionNew operating tables with a much lower adjustability are necessary to fulfill ergonomic requirements. The use of differently designed handles can hinder the ergonomic posture of the surgeon, because each handle requires a different working height.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.