• J Am Soc Echocardiogr · Nov 2015

    Randomized Controlled Trial

    Improving the accuracy of effective orifice area assessment after transcatheter aortic valve replacement: validation of left ventricular outflow tract diameter and pulsed-wave Doppler location and impact of three-dimensional measurements.

    • Omar K Khalique, Nadira B Hamid, Susheel K Kodali, Tamim M Nazif, Leo Marcoff, Jean-Michel Paradis, Mathew R Williams, Torsten P Vahl, Isaac George, Martin B Leon, and Rebecca T Hahn.
    • Columbia University Medical Center/New York-Presbyterian Hospital, New York, New York.
    • J Am Soc Echocardiogr. 2015 Nov 1; 28 (11): 1283-93.

    BackgroundEchocardiographic calculation of effective orifice area (EOA) after transcatheter aortic valve replacement is integral to the assessment of transcatheter heart valve (THV) function. The aim of this study was to determine the most accurate method for calculating the EOA of the Edwards SAPIEN and SAPIEN XT THVs.MethodsOne hundred intraprocedural transesophageal echocardiograms were analyzed. To calculate the post-transcatheter aortic valve replacement left ventricular outflow tract (LVOT) stroke volume (SV), four diameters were measured using two-dimensional echocardiography: (1) baseline LVOT diameter (LVOTd_PRE), (2) postimplantation LVOT diameter, (3) native aortic annular diameter, and (4) THV in-stent diameter. Four corresponding areas were planimetered by three-dimensional echocardiography. Two LVOT velocity-time integrals (VTI) were measured with the pulsed-wave Doppler sample volume at (1) the proximal (apical) edge of the valve stent or (2) within the valve stent at the level of the THV cusps. LVOT velocity-time integral with the sample volume at the proximal edge of the valve stent was used with the LVOT and aortic annular measurements above, whereas in-stent VTI was paired with the in-stent THV diameter to yield eight different SVs. Right ventricular outflow tract (RVOT) SV was calculated using RVOT diameter and RVOT VTI and was used as the primary comparator. Transaortic VTI was obtained by continuous-wave Doppler, and EOA calculations using each SV measurement were compared with (1) EOA calculated using RVOTSV and (2) planimetered aortic valve area using three-dimensional echocardiography (AVAplanimetry3D).ResultsPost-transcatheter aortic valve replacement EOA calculated using LVOTd_PRE was not significantly different from EOA calculated using RVOTSV (1.88 ± 0.33 vs 1.86 ± 0.39 cm(2), P = .36) or from AVAplanimetry3D (1.85 ± 0.28, P = .38, n = 34). All other two-dimensional EOA calculations were statistically larger than EOA calculated using RVOTSV. All three-dimensional echocardiography-based EOA calculations were statistically different from AVAplanimetry3D.ConclusionsThe most accurate EOA after implantation of a balloon-expandable THV is calculated using preimplantation LVOT diameter and VTI.Copyright © 2015 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.