• Spine · Jun 2000

    Case Reports

    Femoral artery ischemia during spinal scoliosis surgery detected by posterior tibial nerve somatosensory-evoked potential monitoring.

    • D G Vossler, T Stonecipher, and M D Millen.
    • Neuroscience Institute and Epilepsy Center, Swedish Medical Center, Seattle, Washington 98122, USA. dvossle@swedish.org
    • Spine. 2000 Jun 1; 25 (11): 1457-9.

    Study DesignA case report of unilateral leg ischemia caused by femoral artery compression detected using posterior tibial nerve somatosensory-evoked potentials during spinal scoliosis instrumentation surgery.ObjectivesTo report a rare cause of intraoperative unilateral loss of all posterior tibial nerve somatosensory-evoked potential waveforms.Summary Of Background DataFailure to obtain adequate popliteal fossa, spinal, subcortical, and cortical potentials during posterior tibial nerve somatosensory-evoked potential spinal cord monitoring usually results from technical factors or chronic conditions affecting the peripheral nerve.MethodsA 16-year-old boy with thoracic scoliosis had normal posterior tibial nerve somatosensory-evoked potentials both before surgery and in the operating room immediately after anesthesia induction and prone positioning on a four-post spinal frame.ResultsOne hour after the start of surgery, a minimal amplitude reduction of the right popliteal fossa potentials appeared. Fifteen minutes later, the amplitudes of the popliteal fossa, subcortical, and cortical potentials evoked by right posterior tibial nerve stimulation became substantially reduced. Subsequently, all waveforms were lost. Malfunction of the right posterior tibial nerve stimulator was initially suspected, but when proper function was verified, a search for other causes of this loss led to discovery of leg ischemia. The patient was repositioned on the spinal frame, and all posterior tibial nerve somatosensory-evoked potentials waveforms began to reappear 7 minutes later. There was no postoperative clinically detectable complication.ConclusionsAlthough technical malfunction should always be suspected when all intraoperative somatosensory-evoked potential waveforms are initially seen and subsequently lost, one should also consider the possibility that intraoperative ischemia due to limb positioning could be the etiology.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…