• Ann Vasc Surg · Nov 2004

    Retrieving "nonretrievable" inferior vena caval Greenfield filters: a therapeutic option for filter malpositioning.

    • Matthew A Corriere, Marc A Passman, Raul J Guzman, Jeffery B Dattilo, and Thomas C Naslund.
    • Division of Vascular Surgery, Vanderbilt University Medical Center, 1161 22nd Avenue South, D5237 MCN, Nashville, TN 37232, USA.
    • Ann Vasc Surg. 2004 Nov 1; 18 (6): 629-34.

    AbstractFilter malpositioning is a possible complication of inferior vena caval (IVC) filter insertion that may result in inadequate protection from pulmonary embolism. For nonretrievable filters, this is traditionally managed with either observation or additional filter placement. The purpose of this study is determine the incidence of filter malpositioning after bedside insertion under duplex ultrasound (DUS) or intravascular ultrasound (IVUS) guidance, and to report techniques for retrieving and repositioning IVC filters previously considered nonretrievable. All IVC filter insertions performed under DUS or IVUS guidance over an 8-year period were identified. Data regarding insertion technique, device used, and technical success were retrospectively collected. Cases of IVC filter malpositioning were determined and form the basis of this study. Technical details for IVC filter retrieval and repositioning are described. Of 486 patients undergoing DUS (n = 435) or IVUS (n = 51) guided IVC filter insertion, 12 patients (2.4%) had inadequate positioning as determined by postoperative radiography. Two of these patients had no further filter manipulation, three had a second filter placed under fluoroscopic guidance, and the most recent five had filters retrieved and repositioned under fluoroscopic guidance. Of those patients undergoing retrieval and repositioning, all five had Greenfield filters, which are not traditionally regarded as retrievable. All attempted retrievals or replacements were technically successful without additional filter-related complications. Bedside IVC filter insertion under DUS or IVUS guidance has a low incidence of filter misplacement. Although not traditionally regarded as retrievable, Greenfield filters can be safely retrieved and repositioned using advanced endovascular techniques in the event of malpositioning.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…