-
Multicenter Study
A multicenter evaluation of a new quantitative highly sensitive D-dimer assay for exclusion of venous thromboembolism.
- Philippe de Moerloose, Gualtiero Palareti, Carlos Aguilar, Cristina Legnani, Guido Reber, and Dirk Peetz.
- Angiology and Haemostasis Division, University Hospital of Geneva and Faculty of Medicine, Geneva Switzerland. philippe.demoerloose@hcuge.ch
- Thromb Haemostasis. 2008 Sep 1; 100 (3): 505-12.
AbstractD-dimer testing is widely applied for exclusion of deep-vein thrombosis (DVT) and pulmonary embolism (PE). We report on a multicenter performance evaluation of a new particle-enhanced immunoassay, Innovance D-Dimer. Innovance D-Dimer assay was performed in 1,543 frozen samples from outpatients suspected of DVT and/or PE enrolled in three management studies as well as in a routine clinical practice. Samples were assayed on BCS/BCS XP, BCT as well as Sysmex CA-7000, CA-1500 and CA-560 analyzers (cut-off on all analyzers: 0.5 mg/l). Stratus CS D-Dimer and Vidas D-Dimer Exclusion were used for comparison. The precision study indicated total coefficients of variation ranging from 2.1% to 8.4% depending on the analyzer and on the sample. Sensitivity and negative predictive values were above 99% and their lower 95% confidence interval were equal or above 97.4% and 98.6%, respectively. Specificity ranged from 38.2% to 40.4% and the respective lower 95% confidence intervals from 35.5% to 37.7%. Area under the curve was 0.90 for all assay systems except for Innovance D-Dimer with BCT (0.89). Two samples from patients with distal DVT tested negative with all assay systems. One patient with high pre-test clinical probability and proximal DVT tested negative with Vidas D-Dimer Exclusion. Our data indicate that the performances of Innovance D-Dimer, regardless of the analyzer, are similar to the reference methods, and that this assay can be used for the exclusion of venous thromboembolic disease.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.