• Int Orthop · Mar 2019

    Clinical application of a minimally invasive cement-augmentable Schanz screw rod system to treat pelvic ring fractures.

    • Paul Schmitz, Florian Baumann, Yves P Acklin, Boyko Gueorguiev, Michael Nerlich, Stephan Grechenig, and Michael Bernd Müller.
    • Clinic of Traumatology, University Medical Center Regensburg, Franz-Josef-Strauss Allee 11, 93053, Regensburg, Germany. paul.schmitz@ukr.de.
    • Int Orthop. 2019 Mar 1; 43 (3): 697-703.

    PurposeThe purpose of this study is to analyze the results using the USS fracture MIS system (DePuy Synthes) to treat instable pelvic ring fractures. As its outstanding feature, it is the only Schanz screw and rod system at present that combines angular stability, perforation/fenestration of the screws for cement-augmentation, a variable screw length, and a large screw diameter.Materials And MethodsRetrospective investigation of 134 pelvic ring fractures treated in 2012-2013. Twenty-five patients obtained the abovementioned implant. Besides baseline characteristics of the included patients and the surgical procedure, a clinical/radiological follow-up of six months was analyzed.ResultsDividing the collective into two groups, I high-energy trauma and II fragility fracture of the pelvis, the following results were recorded: group I: ten patients, six male, age 48.4 ± 19.7 years. Mean ISS 41 ± 22.5, fracture classification: AO/OTA type 61 B1/C1/C3 = 1/5/4. Operative treatment: three transiliac internal fixator, seven iliolumbar fixation, one implant was cement-augmented. Group II: 15 patients, 14 female, age 77.5 ± 10.1 years. Fracture classification according to Rommens: FFPII/III/IV = 6/1/8. Operative treatment: eight transiliac internal fixator, seven iliolumbar fixation, 14 implants were cement-augmented. Overall surgical side complications: 16%. Radiological examination: correct positioning of all ilium screws. Follow-up after six month (16 patients): all showed fracture consolidation. One ilium screw was broken close to the connecting clamp.ConclusionThe investigated Schanz screw rod system is a suitable implant to broaden the established procedures to stabilize dorsal pelvic ring fractures.Trial RegistrationThe study is registered at the Clinical Trial Registry University of Regensburg (Number Z-2017-0878-3).

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.