• Spine · Jan 2008

    Enhancing the stability of anterior lumbar interbody fusion: a biomechanical comparison of anterior plate versus posterior transpedicular instrumentation.

    • Michael N Tzermiadianos, Anis Mekhail, Leonard I Voronov, Jason Zook, Robert M Havey, Susan M Renner, Gerard Carandang, Celeste Abjornson, and Avinash G Patwardhan.
    • Department of Orthopaedic Surgery and Rehabilitation, Loyola University Medical Center, Maywood, IL 60153, USA.
    • Spine. 2008 Jan 15; 33 (2): E38-43.

    Study DesignBiomechanical study using human cadaver spines.ObjectiveTo assess the stabilizing effect of a supplemental anterior tension band (ATB, Synthes) plate on L5-S1 anterior lumbar interbody fusion (ALIF) using a femoral ring allograft (FRA) under physiologic compressive preloads, and to compare the results with the stability achieved using FRA with supplemental transpedicular instrumentation.Summary Of Background DataPosterior instrumentation can improve the stability of ALIF cages. Anterior plates have been proposed as an alternative to avoid the additional posterior approach.MethodsEight human specimens (L3 to sacrum) were tested in the following sequence: (i) intact, (ii) after anterior insertion of an FRA at L5-S1, (iii) after instrumentation with the ATB plate, and (iv) after removal of the plate and adding transpedicular instrumentation at the same level. Specimens were tested in flexion-extension, lateral bending, and axial rotation. Flexion-extension was tested under 0 N, 400 N, and 800 N compressive follower preload to simulate physiologic compressive preloads on the lumbar spine.ResultsStand-alone FRAs significantly decreased the range of motion (ROM) in all tested directions (P < 0.05); however, the resultant ROM was large in flexion-extension ranging between 6.1 +/- 3.1 degrees and 5.1 +/- 2.2 degrees under 0 N to 800 N preloads. The ATB plate resulted in a significant additional decrease in flexion-extension ROM under 400 N and 800 N preloads (P < 0.05). The flexion-extension ROM with the ATB plate was 4.1 +/- 2.3 under 0 N preload and ranged from 3.1 +/- 1.8 to 2.4 +/- 1.3 under 400 N to 800 N preloads. The plate did not significantly decrease lateral bending or axial rotation ROM compared with stand-alone FRA (P > 0.05), but the resultant ROM was 2.7 +/-1.9 degrees and 0.9 +/- 0.6 degrees , respectively. Compared with the ATB plate, the transpedicular instrumentation resulted in significantly less ROM in flexion-extension and lateral bending (P < 0.05), but not in axial rotation (P > 0.05).ConclusionThe ATB plate can significantly increase the stability of the anterior FRA at L5-S1 level. Although supplemental transpedicular instrumentation results in a more stable biomechanical environment, the resultant ROM with the addition of a plate is small, especially under physiologic preload, suggesting that the plate can sufficiently resist motion. Therefore, clinical assessment of the ATB plate as an alternative to transpedicular instrumentation to enhance ALIF cage stability is considered reasonable.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…