• Europace · Jan 2010

    Contemporary management of and outcomes from cardiac device related infections.

    • Ronan Margey, Hugh McCann, Gavin Blake, Edward Keelan, Joseph Galvin, Maureen Lynch, Niall Mahon, Declan Sugrue, and James O'Neill.
    • Department of Cardiology, Mater Misericordiae University Hospital, Eccles Street, Dublin 7, Ireland. rmargey@hotmail.com
    • Europace. 2010 Jan 1; 12 (1): 64-70.

    AimsTo describe the incidence and management of cardiac device infection. Infection is a serious, potentially fatal complication of device implantation. The numbers of device implants and infections are rising. Optimal care of device infection is not well defined.Methods And ResultsWe retrospectively identified cases of device infection at our institution between 2000 and 2007 by multiple source record review, and active surveillance. Device infection was related to demographics, clinical, and procedural characteristics. Descriptive analysis was performed. From 2000 to 2007, a total of 2029 permanent pacemakers and 1076 biventricular/implantable cardioverter-defibrillators (ICDs) or ICDs were implanted. Thirty-nine cases of confirmed device infections were identified--27 pacemaker and 12 bivent/ICD or ICD infections, giving an infection rate of 1.25%. Median time from implant or revision to presentation was 150 days (range 2915 days, IQR25% 35-IQR75% 731). Ninety percent of patients presented with generator-site infections. The most common organism was methicillin-sensitive Staphylococcus aureus (30.8%), followed by coagulase negative Staphylococcus (20.5%). Complete device extraction occurred in 82%. Of these, none had relapse, and mortality was 7.4% (n = 2/27). With partial removal or conservative therapy (n = 13), relapse occurred in 67% (n = 8/12), with mortality of 8.4% (n = 1/12). Median duration of antibiotics was 42 days (range 47 days, IQR25% 28-IQR75% 42 days). Re-implantation of a new device occurred in 54%, at a median of 28 days (range 73 days, IQR25% 8.5-IQR75% 35 days). Methicillin-Resistant Staphylococcus Aureus infection predicted mortality (P < 0.004, RR 37, 95% CI 5.3-250). Median follow-up was 36 months.ConclusionCardiac device infection is a rare complication, with significant morbidity and mortality. Complete hardware removal with appropriate duration of antimicrobial therapy results in the best outcomes for patients.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…