Comparative Study
The Diagnostic Utility of Multifocal Electroretinography in Detecting Chloroquine and Hydroxychloroquine Retinal Toxicity.
- Adrian C Tsang, Sina Ahmadi, John Hamilton, Jennifer Gao, Gianni Virgili, Stuart G Coupland, and Chloe C Gottlieb.
- University of Ottawa Eye Institute, The Ottawa Hospital, Ottawa, Ontario, Canada. Electronic address: tsang@uottawa.ca.
- Am. J. Ophthalmol. 2019 Oct 1; 206: 132-139.
PurposeTo evaluate multifocal electroretinography (mfERG) as a screening test for detecting hydroxychloroquine and chloroquine toxicity.DesignDiagnostic accuracy study.MethodsPatients referred to the University of Ottawa for hydroxychloroquine or chloroquine retinopathy screening during 2011-2014 underwent 10-2 automated visual field, spectral domain optical coherence tomography, and mfERG testing. Patients with amblyopia, high myopia or hyperopia, coexisting retinal disease, or prior surgery were excluded. Abnormalities in parafoveal ring amplitudes or ring ratios were considered a positive mfERG result. We used the definition for hydroxychloroquine and chloroquine toxicity provided by the 2016 American Academy of Ophthalmology recommendations. Area under the curve (AUC) for each mfERG parameter and the sensitivity and specificity of mfERG were calculated. Logistic regression was used to model the effect of covariates in receiver operating characteristic (ROC) analyses.ResultsIn total, 63 patients (47 female, 16 male) were included. Of 120 eyes, 16 (13.3%) had toxicity according to the American Academy of Ophthalmology guidelines, and 39 (32.5%) had positive mfERG findings. mfERG was found to have a sensitivity of 1.00 (95% CI 0.79-1.00) and a specificity of 0.78 (95% CI 0.69-0.85). Ring 2 amplitude had the best performance among all parameters (AUC 0.97, 95% CI 0.94-1.00). Ring 2 amplitude decreased linearly with increasing cumulative dose and daily dose.ConclusionsThe high sensitivity of parafoveal depression on mfERG and its relationship to cumulative and daily dose illustrates an important role for objective functional testing. The high false-positive rate suggests a potential period where physiologic dysfunction is detected objectively on mfERG before structural change on spectral domain optical coherence tomography.Copyright © 2019 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.