    Retinal imaging with optical coherence tomography and low-loss adaptive optics using a 2.8-mm beam size.

    • Reddikumar Maddipatla, Joel Cervantes, Yukitoshi Otani, and Barry Cense.
    • Center for Optical Research and Education, Utsunomiya University, Utsunomiya, Japan.
    • J Biophotonics. 2019 Jun 1; 12 (6): e201800192.

    AbstractAs data acquisition for retinal imaging with optical coherence tomography (OCT) becomes faster, efficient collection of photons becomes more important to maintain image quality. One approach is to use a larger aperture at the eye's pupil to collect more photons that have been reflected from the retina. A 2.8-mm beam diameter system with only seven reflecting surfaces was developed for low-loss retinal imaging. The larger beam size requires defocus and astigmatism correction, which was done in a closed loop adaptive optics method using a Shack-Hartmann wavefront sensor and a deformable mirror (DM) with 140 actuators and a ±2.75 μm stroke. This DM facilitates defocus correction ranging from approximately -3 D to +3 D. Comparing the new system with a standard 1.2-mm system on a model eye, a signal-to-noise gain of 4.5 dB and a 2.3 times smaller speckle size were measured. Measurements on the retinas of five subjects showed even better results, with increases in dynamic range up to 13 dB. Note that the new sample arm only occupies 30 cm × 60 cm, which makes it highly suitable for imaging in a clinical environment. Figure: B-scan images obtained over a width of 8 deg from the right eye of a 31-year-old Caucasian male. While the left side was imaged with a standard 1.2-mm OCT system, the right side was imaged with the 2.8-mm system. Both images were collected with the same integration time and incident power, after correction of aberrations. Using the dynamic range within the images, which is determined by comparing the highest pixel value to the noise floor, a difference in dynamic range of 10.8 dB was measured between the two systems.© 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.