• Anesthesia and analgesia · Apr 2002

    Does indocyanine green accurately measure plasma volume early after cardiac surgery?

    • Hironori Ishihara, Hirobumi Okawa, Tsutomu Iwakawa, Noriko Umegaki, Toshihito Tsubo, and Akitomo Matsuki.
    • Department of Anesthesiology, University of Hirosaki School of Medicine, Hirosaki-Shi, Japan. ishihara@cc.hirosaki-u.ac.jp
    • Anesth. Analg. 2002 Apr 1; 94 (4): 781-6, table of contents.

    UnlabelledPotential overestimation of plasma volume (PV) determination by the conventional indocyanine green (ICG) dilution method (PV-ICG) can occur when generalized capillary protein leakage is present, because ICG binds to proteins. We recently reported that this overestimation can be recognized by simultaneous measurement of the initial distribution volume of glucose (IDVG). We examined whether overestimation of PV-ICG and further ICG-pulse dye densitometry-derived plasma volume (PV-PDD) can occur early after cardiac surgery by using the PV-ICG/IDVG ratio as an indicator. Possible overestimation was defined as a ratio higher than 0.45. Twenty-four consecutive postcardiac surgical patients were enrolled. PV-ICG, PV-PDD, and IDVG were calculated simultaneously after admission to the intensive care unit and on the first postoperative day. The mean +/- SD PV-ICG/IDVG ratio for 47 recordings was 0.38 +/- 0.05. Four had a PV-ICG/IDVG ratio higher than 0.45, and the highest was 0.48. The mean PV-PDD/IDVG ratio for a total of 47 recordings was 0.39 +/- 0.10. There were extremely high or low ratios observed in PV-PDD determinations, but they were not observed in PV-ICG determinations. Results suggest that most of the PV-ICG measurements are accurate, but inaccuracy of PV-PDD can occur early after cardiac surgery.ImplicationsOverestimation of indocyanine green-derived plasma volume can occur in the presence of generalized capillary protein leakage. This overestimation was examined early after cardiac surgery by using the simultaneous measurement of the initial distribution volume of glucose. We suggest that overestimation of the traditional dye dilution method is negligible, but apparent over- or underestimation of pulse dye densitometry-derived plasma volume cannot be negligible.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…