• Artificial organs · Apr 2017

    Comparative Study

    Building a Better Neonatal Extracorporeal Life Support Circuit: Comparison of Hemodynamic Performance and Gaseous Microemboli Handling in Different Pump and Oxygenator Technologies.

    • Kristen Glass, Payal Trivedi, Shigang Wang, Karl Woitas, Allen R Kunselman, and Akif Ündar.
    • Department of Pediatrics, Penn State Hershey Pediatric Cardiovascular Research Center, Penn State Hershey College of Medicine, Penn State Hershey Children's Hospital, Hershey, PA, USA.
    • Artif Organs. 2017 Apr 1; 41 (4): 392-400.

    AbstractNeurologic complications during neonatal extracorporeal life support (ECLS) are associated with significant morbidity and mortality. Gaseous microemboli (GME) in the ECLS circuit may be a possible cause. Advances in neonatal circuitry may improve hemodynamic performance and GME handling leading to reduction in patient complications. This study compared hemodynamic performance and GME handling using two centrifugal pumps (Maquet RotaFlow and Medos Deltastream DP3) and polymethylpentene oxygenators (Maquet Quadrox-iD and Medos Hilite 800LT) in a neonatal ECLS circuit model. The experimental circuit was primed with Lactated Ringer's solution and packed human red blood cells (hematocrit 40%) and arranged in parallel with the RotaFlow and DP3 pump, Quadrox-iD and Hilite oxygenator, and Better-Bladder. Hemodynamic trials evaluating pressure drops and total hemodynamic energy (THE) were conducted at 300 and 500 mL/min at 36°C. GME handling was measured after 0.5 mL of air was injected into the venous line using the Emboli Detection and Classification Quantifier System with unique pump, oxygenator, and Better-Bladder combinations. The RotaFlow pump and Quadrox oxygenator arrangement had lower pressure drops and THE loss at both flow rates compared to the DP3 pump and Hilite oxygenator (P < 0.01). Total GME volume and counts decreased with Better-Bladder at both flow rates with all combinations (P < 0.01). Hemodynamic performance and energy loss were similar in all of the circuit combinations. The Better-Bladder significantly decreased GME. All four combinations of pumps and oxygenators also performed similarly in terms of GME handling.© 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.