• Spine · Sep 2009

    In situ contact analysis of the prosthesis components of Prodisc-L in lumbar spine following total disc replacement.

    • Wen-Ming Chen, ChunKun Park, KwonYong Lee, and SungJae Lee.
    • Division of Bioengineering, National University of Singapore, Singapore.
    • Spine. 2009 Sep 15; 34 (20): E716-23.

    Study DesignA three-dimensional, nonlinear finite element analysis was performed to predict the in situ contact interaction of prosthesis components of the Prodisc-L in a multisegmental lumbar model following total disc replacement (TDR).ObjectiveEfforts were made to investigate how the TDR implant contact characteristics could affect the 3-dimensional kinematics, facet loads of the lumbar spine following TDR.Summary Of Background DataAlthough spinal motion analyses of human lumbar cadaveric models after Prodisc TDR have been widely studied, the interaction of the disc prosthesis, particularly its in situ contact mechanics, is never known.MethodsA validated intact multisegmental lumbar finite element model L2-L4 was altered to accommodate the TDR prosthesis through anterior approach. At L3-L4 disc space, the Prodisc-L of 6 degrees lordosis angle was implanted centrally. The model was subjected to compressive preload and pure moments to create flexion, extension, lateral bending, and axial rotation motion in physiologic range. The contact interaction between the superior component of Prodisc-L and the UHMWPE inlay were assessed in terms of contact region (CR), contact area (CA), and contact pressure (CP). Parameters of range of motion (ROM) and facet loading transfer were simultaneously analyzed and compared with those of the intact model.ResultsThe predicted contact area was 3.5 times larger in flexion than that observed in extension, whereas the maximum contact pressure in the disc articulation was very similar with 15.1 MPa for flexion and 14.5 MPa for extension. Joint surface incongruence was developed in extension motion. The implanted model exhibited a 91.4% increase in ROM accompanied by a 150.6% rising in facet force during extension, while the flexion motion showed the least effects of TDR. In lateral bending and axial rotation, the abnormal joint "lift off" was not seen.ConclusionThe in situ function of the TDR prosthesis was highly dependent on how well the device could incorporate itself into the mechanical environment in the disc space, which has been determined by the rest of the spinal structures, including the retained disc anulus, articular facets, ligaments, vertebrae, and muscular stabilizers. The different contact interaction of the artificial disc components revealed here could be attributed to the violation of this mechanical environment which, in turn, may bring adverse effects to those spinal elements.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…