• Chest · Apr 1995

    Specificity and sensitivity of respiratory impedance in assessing reversibility of airway obstruction in children.

    • H K Mazurek, F Marchal, J Derelle, R Hatahet, D Moneret-Vautrin, and P Monin.
    • Laboratoire d'Exploration Fonctionnelles Pédiatriques, Hôpital d'Enfants Service de Médecine D, Centre Hospitalier Universitaire de Nancy, France.
    • Chest. 1995 Apr 1; 107 (4): 996-1002.

    AbstractFlow in the upper airway wall induces significant error in estimating respiratory impedance by the standard forced oscillation technique in subjects with airway obstruction and may be minimized by oscillating pressure around the subject's head (head generator technique). The aim of this study was to determine whether the latter improves the power of forced oscillations in detecting airway response to bronchodilators in children. Seventy-five children with airway obstruction were studied (ages 5.5 to 15 years old). Fifty-three had asthma and 22, cystic fibrosis. A bronchodilator was administered, and the percent changes in respiratory resistance at 10 Hz (Rrs10), 20 Hz (Rrs20), respiratory compliance (Crs), and resonant frequency (fn) with standard and head generator were compared with the corresponding change in FEV1. The response was positive in 38 (delta % FEV1 > or = 15%) and negative in 37 patients. Data on Rrs10, Crs, and fn could not be obtained in 7, 8, and 4 subjects, respectively, for technical reasons. The delta % Rrs20 was not different between head and standard generator in nonresponders (mean +/- SEM: -19.0 +/- 4.5, vs -11.8 +/- 3.1%), but significantly larger with head than standard generator in responders (-54.1 +/- 3.0 vs -26.5 +/- 2.4%; p < 0.001). The optimal decision level determined by Receiver Operation Characteristic analysis showed that, compared with the standard method, the head generator improved the specificity of Rrs20 (78 vs 65%) with no change in sensitivity (76% for both). Resonant frequency had larger sensitivity with standard than with head generator (91 vs 53%) but slightly lower specificity (70 vs 78%). Finally, delta %Crs was more specific (72 vs 67%) and more sensitive (68 vs 52%) with standard than with head generator. The overall incidence of false results was lower with the head generator than with the standard generator for resistance and lower with the standard generator than with the head generator for fn and compliance. Thus, the head generator improves the diagnostic power of the forced oscillation resistance in establishing the reversibility of airway obstruction, but parameters derived from the reactance may have better diagnostic value with the standard method.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.