-
Int J Obstet Anesth · Feb 2021
Randomized Controlled TrialThe effect of baricity of intrathecal bupivacaine for elective cesarean delivery on maternal cardiac output: a randomized study.
- P Limratana, T Kiatchai, P Somnuke, P Prapakorn, and S Suksompong.
- Department of Anesthesiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Thailand.
- Int J Obstet Anesth. 2021 Feb 1; 45: 61-66.
BackgroundHemodynamic instability during spinal anesthesia for cesarean delivery is associated with adverse maternal and fetal outcomes. Plain and hyperbaric bupivacaine are commonly used for cesarean delivery, however, their distinctive pharmacologic properties may affect maternal hemodynamic profiles differently. The aim of this study was to compare hemodynamic profiles using a suprasternal Doppler cardiac output (CO) monitor in healthy term parturients randomized to receive plain or hyperbaric bupivacaine for cesarean delivery.MethodsOne hundred-and-sixty-eight healthy parturients scheduled for elective cesarean delivery were randomly assigned to receive 10.9 mg of intrathecal 0.5% plain or hyperbaric bupivacaine, both with 0.2 mg morphine. The primary outcome was CO change after spinal anesthesia. Secondary outcomes were the incidence of hypotension, vasopressor use, and conversion to general anesthesia.ResultsThe mean (±SD) CO at baseline, 1 min and 5 min after spinal anesthesia, and after placental delivery was 4.6 ± 1.2, 5.4 ± 1.3, 5.1 ± 1.4, and 6.4 ± 1.7 L/min in the plain bupivacaine, and 4.5 ± 1.1, 5.2 ± 1.3, 4.9 ± 1.3, and 6.2 ± 1.9 L/min in the hyperbaric bupivacaine group. There were no significant differences in CO, mean arterial pressure, or systemic vascular resistance. Incidences of hypotension, vasopressor and supplemental analgesic use, and conversion to general anesthesia, were not different between groups.ConclusionsCardiac output changes after plain or hyperbaric bupivacaine were not different in term parturients undergoing spinal anesthesia for cesarean delivery. Further studies comparing block quality and the rate of conversion to general anesthesia are required.Copyright © 2020 Elsevier Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.