-
- Stephen Sanchez, Matthew Miller, and Stephen Asha.
- St Vincent's Hospital Darlinghurst Australia.
- Resuscitation. 2020 Dec 1; 157: 67-73.
BackgroundTraditional assessment of return of cardiac output in cardiac arrest by manual palpation has poor accuracy. Point of care ultrasound of a major artery has been suggested as an alternative. We conducted a diagnostic accuracy study of two-dimensional carotid ultrasound to detect the presence or absence of a pulse, using cardiopulmonary bypass patients for pulse and pulseless states.MethodsA cross-sectional multi-patient, multi-reader repeated measures diagnostic study was conducted. For patients undergoing routine cardiopulmonary bypass, a portable ultrasound was used to record four 10-s videos the common carotid artery, three aimed for a pulse in high (>90 mmHg), medium (70-90 mmHg) and low (<70 mmHg) systolic blood pressure (SBP) ranges, and a pulseless video was recorded on cardiopulmonary bypass. Critical care physicians viewed the videos and were asked to nominate within 10 s if a pulse was present. True pulse-status was determined via the arterial-line waveform.ResultsTwenty-three patients had all four videos collected. Median patient age was 64 (IQR 14), sixteen were male (70%) and median BMI was 27. The median SBP in high-, medium- and low-SBP groups were 120 mmHg, 83 mmHg and 69 mmHg respectively. Forty-six physicians reviewed a subset of 24 videos. Overall sensitivity was 0.91 (95% confidence interval 0.89-0.93) and specificity 0.90 (95% CI 0.86-0.93). Sensitivity was highest in the high-SBP group (0.96, 95% CI 0.93-0.98) and lowest in the low-SBP group (0.83, 95% CI 0.78-0.87).Conclusion2D ultrasound of the common carotid artery is both sensitive and specific for detection of the presence or absence of a pulse.Copyright © 2020 Elsevier B.V. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.