• Heart Rhythm · Sep 2005

    Idiopathic fascicular left ventricular tachycardia: linear ablation lesion strategy for noninducible or nonsustained tachycardia.

    • David Lin, Henry H Hsia, Edward P Gerstenfeld, Sanjay Dixit, David J Callans, Hemal Nayak, Andrea Russo, and Francis E Marchlinski.
    • Hospital of the University of Pennsylvania, University of Pennsylvania Health Systems, Department of Medicine, Electrophysiology Section, Philadelphia, Pennsylvania 19104, USA. david.lin@uphs.upenn.edu
    • Heart Rhythm. 2005 Sep 1; 2 (9): 934-9.

    BackgroundIdiopathic "fascicular" left ventricular tachycardia (IFLVT) is frequently not inducible or nonsustained at the time of planned catheter ablation. The mechanism of the arrhythmia has been suggested to be reentry involving a sizable area of the LV inferior septum extending from base toward the apex.ObjectiveWe tested the ability of a series of radiofrequency lesions delivered in a linear fashion to the inferior-mid septum to control ventricular tachycardia not amenable to standard mapping ablation strategies.MethodsProgrammed stimulation both at baseline state and with isoproterenol after heart rate was increased by at least 25% was performed in all patients. The patients included in the study were either non-inducible or only had brief nonsustained VT not amenable to "traditional" mapping. A detailed electroanatomic map of the LV was performed in sinus rhythm. The location of the linear lesion along the inferior septum was guided by the presence of Purkinje potentials, with pacemapping as an additional guide. A linear lesion was placed perpendicular to the long axis of the ventricle approximately midway from the base to the apex in the region of the mid to mid-inferior septum. Radiofrequency lesions were delivered using a 4mm tip catheter at 50 Watts and 52 degrees for 60-90 seconds.ResultsOf 122 consecutive patients who underwent ablation of idiopathic VT from 1999 to 2003, 15 had IFLVT based on standard diagnostic criteria. Six of the 15 patients (40%) had nonsustained or no inducible VT in the EP lab. The number of RF lesions ranged from 7 to 15 (mean 9). The length of the effective linear lesion ranged from 1.2 to 2.2 cm (mean 1.7 cm). Development of left posterior fascicular block was noted in two of the six patients. However, despite the absence of development of left posterior fascicular block in the other four patients, no VT or premature ventricular beats could be induced after ablation using the same provocation maneuvers as performed in the baseline state. No spontaneous arrhythmias occurred during follow-up to 16 +/- 8 months (range 6 to 30 months).ConclusionIn patients with difficult to induce or nonsustained VT with the typical right bundle branch block pattern and a superiorly directed axis on 12-lead ECG, RF energy ablation delivered in a linear fashion approximately midway to two thirds toward the apex along the mid to inferior septum and perpendicular to the plane of the septum is safe and effective for VT control.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.