• J Bone Joint Surg Am · Mar 2009

    A nonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis.

    • Michael Bottlang, Josef Doornink, Gregory D Byrd, Daniel C Fitzpatrick, and Steven M Madey.
    • Legacy Biomechanics Laboratory, 1225 N.E. 2nd Avenue, Portland, OR 97215, USA.
    • J Bone Joint Surg Am. 2009 Mar 1; 91 (3): 620-7.

    BackgroundLocking plates transmit load through fixed-angle locking screws instead of relying on plate-to-bone compression. Therefore, locking screws may induce higher stress at the screw-bone interface than that seen with conventional nonlocked plating. This study investigated whether locked plating in osteoporotic diaphyseal bone causes a greater periprosthetic fracture risk than conventional plating because of stress concentrations at the plate end. It further investigated the effect of replacing the locked end screw with a conventional screw on the strength of the fixation construct.MethodsThree different bridge-plate constructs were applied to a validated surrogate of the osteoporotic femoral diaphysis. Constructs were tested dynamically to failure in bending, torsion, and axial loading to determine failure loads and failure modes. A locked plating construct was compared with a nonlocked conventional plating construct. Subsequently, the outermost locking screw in locked plating constructs was replaced with a conventional screw to reduce stress concentrations at the plate end.ResultsCompared with the conventional plating construct, the locked plating construct was 22% weaker in bending (p = 0.013), comparably strong in torsion (p = 0.05), and 15% stronger in axial compression (p = 0.017). Substituting the locked end screw with a conventional screw increased the construct strength by 40% in bending (p = 0.001) but had no significant effect on construct strength under torsion (p = 0.22) and compressive loading (p = 0.53) compared with the locked plating construct. Under bending, all constructs failed by periprosthetic fracture.ConclusionsUnder bending loads, the focused load transfer of locking plates through fixed-angle screws can increase the periprosthetic fracture risk in the osteoporotic diaphysis compared with conventional plates. Replacing the outermost locking screw with a conventional screw reduced the stress concentration at the plate end and significantly increased the bending strength of the plating construct compared with an all-locked construct (p = 0.001).

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.