- Dave J Dalstrom, Dave B Nelles, Vinit Patel, Tarun Goswami, Ronald J Markert, and Michael J Prayson.
- Department of Orthopaedic Surgery, Wright State University, Dayton, OH, USA.
- J Orthop Trauma. 2012 Sep 1; 26 (9): 523-7.
ObjectiveTo examine the impact of number and position of locking screws in the diaphyseal portion of an osteoporotic distal femoral fracture model with hybrid fixation.MethodsFour groups containing 5 osteoporotic bone models were used with varying combinations of diaphyseal screw fixation: 4 nonlocking screws (control); 1 locking screw adjacent to the osteotomy and 3 nonlocking screws; 1 locking screw in the most proximal screw hole of the plate and 3 nonlocking screws; and 2 locking screws at opposite ends of the diaphyseal fixation with 2 nonlocking screws in between. Fixation in the distal articular segment was identical in all constructs. Testing was performed for 50,000 cycles at 2 Hz using simultaneous axial compression (700 N) and bidirectional torque (±5 Nm) applied along the long axis of the bone. All screws were inserted with 4 Nm of torque.ResultsThe extraction torque for nonlocking screws in those specimens that had a locking screw nearest the osteotomy was significantly greater than those that did not (P = 0.037). In addition, the 10 constructs with a locking screw nearest the osteotomy had no failures compared with 5 of 10 failures in those without a locking screw in this position (P = 0.033).ConclusionsThe placement of a locking screw adjacent to the osteotomy was more beneficial in protecting against failure and maintaining the extraction torque of neighboring proximal nonlocking screws. No benefit in adjacent screw extraction torque was seen with a locking screw proximal in the diaphysis. Two locking screws at opposite ends of the diaphyseal fixation were not superior to a single locking screw adjacent to the osteotomy in failure rates or screw extraction torque.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.