• World Neurosurg · Feb 2021

    Comparing Occlusive Balloon Performance Using 3D Printed Models of Intracranial Aneurysmal Defects.

    • Joseph Knox, Ryan Sincic, David B McCoy, Colby Sostarich, and Daniel L Cooke.
    • Department of Radiology, University of California, San Francisco, California, USA. Electronic address: Joey.knx@gmail.com.
    • World Neurosurg. 2021 Feb 1; 146: e888-e895.

    ObjectiveBalloon remodeling microcatheters are essential in assisting endovascular coiling of brain aneurysms, but the performance and pressure requirements of different balloon types when used in aneurysmal defects are currently unknown.MethodsWe used Tinkercad (Autodesk, Montreal, Quebec) to create model vessels with aneurysmal defects and 3-dimensionally printed these designs with polylactic acid using the Ultimaker2 (Ultimaker, Geldermalsen, Netherlands). We constructed a pressurized box capable of reaching physiologic pressures that housed our vessels and then tested compliant remodeling balloons under fluoroscopy from 3 manufacturers: Hyperglide (Medtronic, Minneapolis, Minnesota, USA), Transform (Stryker Neurovascular, Fremont, California, USA), and Scepter C (Microvention, Tustin, California, USA). Each balloon was inflated to a nominal and supranominal point at each defect, and at each inflation the maximum diameter of the balloon and internal balloon pressure were recorded. The Phillips Intellivue (Phillips, Amsterdam, The Netherlands) monitor was adapted for internal balloon pressure monitoring. A multivariate linear regression analysis was performed to model balloon compliance (balloon diameter divided by pressure).ResultsMultivariate regression modeling demonstrated the Scepter balloon had significantly greater compliance compared with both the Hyperglide and Transform balloons (P < 0.001). In addition, we found that Scepter balloons had higher compliance in larger defects compared with the other types of balloons and performance differences based on vessel size.ConclusionsScepter balloons require less pressure compared with their counterparts to adequately deform through model defects, specifically in larger aneurysm necks in smaller vessel diameters. This result could inform operators of optimal balloon type and size when trying to minimize balloon pressure in fragile brain aneurysms.Copyright © 2020 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…