    • Nayaar Islam, Jean-Paul Salameh, Mariska Mg Leeflang, Lotty Hooft, Trevor A McGrath, Christian B van der Pol, Robert A Frank, Sakib Kazi, Ross Prager, Samanjit S Hare, Carole Dennie, René Spijker, Jonathan J Deeks, Jacqueline Dinnes, Kevin Jenniskens, Daniël A Korevaar, Jérémie F Cohen, Ann Van den Bruel, Yemisi Takwoingi, Janneke van de Wijgert, Junfeng Wang, Matthew Df McInnes, and Cochrane COVID-19 Diagnostic Test Accuracy Group.
    • Department of Radiology, University of Ottawa, Ottawa, Canada.
    • Cochrane Db Syst Rev. 2020 Nov 26; 11: CD013639.

    BackgroundThe respiratory illness caused by SARS-CoV-2 infection continues to present diagnostic challenges. Early research showed thoracic (chest) imaging to be sensitive but not specific in the diagnosis of coronavirus disease 2019 (COVID-19). However, this is a rapidly developing field and these findings need to be re-evaluated in the light of new research. This is the first update of this 'living systematic review'. This update focuses on people suspected of having COVID-19 and excludes studies with only confirmed COVID-19 participants.ObjectivesTo evaluate the diagnostic accuracy of thoracic imaging (computed tomography (CT), X-ray and ultrasound) in people with suspected COVID-19.Search MethodsWe searched the COVID-19 Living Evidence Database from the University of Bern, the Cochrane COVID-19 Study Register, The Stephen B. Thacker CDC Library, and repositories of COVID-19 publications through to 22 June 2020. We did not apply any language restrictions.Selection CriteriaWe included studies of all designs that recruited participants of any age group suspected to have COVID-19, and which reported estimates of test accuracy, or provided data from which estimates could be computed. When studies used a variety of reference standards, we retained the classification of participants as COVID-19 positive or negative as used in the study.Data Collection And AnalysisWe screened studies, extracted data, and assessed the risk of bias and applicability concerns using the QUADAS-2 domain-list independently, in duplicate. We categorised included studies into three groups based on classification of index test results: studies that reported specific criteria for index test positivity (group 1); studies that did not report specific criteria, but had the test reader(s) explicitly classify the imaging test result as either COVID-19 positive or negative (group 2); and studies that reported an overview of index test findings, without explicitly classifying the imaging test as either COVID-19 positive or negative (group 3). We presented the results of estimated sensitivity and specificity using paired forest plots, and summarised in tables. We used a bivariate meta-analysis model where appropriate. We presented uncertainty of the accuracy estimates using 95% confidence intervals (CIs).Main ResultsWe included 34 studies: 30 were cross-sectional studies with 8491 participants suspected of COVID-19, of which 4575 (54%) had a final diagnosis of COVID-19; four were case-control studies with 848 cases and controls in total, of which 464 (55%) had a final diagnosis of COVID-19. Chest CT was evaluated in 31 studies (8014 participants, 4224 (53%) cases), chest X-ray in three studies (1243 participants, 784 (63%) cases), and ultrasound of the lungs in one study (100 participants, 31 (31%) cases). Twenty-six per cent (9/34) of all studies were available only as preprints. Nineteen studies were conducted in Asia, 10 in Europe, four in North America and one in Australia. Sixteen studies included only adults, 15 studies included both adults and children and one included only children. Two studies did not report the ages of participants. Twenty-four studies included inpatients, four studies included outpatients, while the remaining six studies were conducted in unclear settings. The majority of included studies had a high or unclear risk of bias with respect to participant selection, index test, reference standard, and participant flow. For chest CT in suspected COVID-19 participants (31 studies, 8014 participants, 4224 (53%) cases) the sensitivity ranged from 57.4% to 100%, and specificity ranged from 0% to 96.0%. The pooled sensitivity of chest CT in suspected COVID-19 participants was 89.9% (95% CI 85.7 to 92.9) and the pooled specificity was 61.1% (95% CI 42.3 to 77.1). Sensitivity analyses showed that when the studies from China were excluded, the studies from other countries demonstrated higher specificity compared to the overall included studies. When studies that did not classify index tests as positive or negative for COVID-19 (group 3) were excluded, the remaining studies (groups 1 and 2) demonstrated higher specificity compared to the overall included studies. Sensitivity analyses limited to cross-sectional studies, or studies where at least two reverse transcriptase polymerase chain reaction (RT-PCR) tests were conducted if the first was negative, did not substantively alter the accuracy estimates. We did not identify publication status as a source of heterogeneity. For chest X-ray in suspected COVID-19 participants (3 studies, 1243 participants, 784 (63%) cases) the sensitivity ranged from 56.9% to 89.0% and specificity from 11.1% to 88.9%. The sensitivity and specificity of ultrasound of the lungs in suspected COVID-19 participants (1 study, 100 participants, 31 (31%) cases) were 96.8% and 62.3%, respectively. We could not perform a meta-analysis for chest X-ray or ultrasound due to the limited number of included studies.Authors' ConclusionsOur findings indicate that chest CT is sensitive and moderately specific for the diagnosis of COVID-19 in suspected patients, meaning that CT may have limited capability in differentiating SARS-CoV-2 infection from other causes of respiratory illness. However, we are limited in our confidence in these results due to the poor study quality and the heterogeneity of included studies. Because of limited data, accuracy estimates of chest X-ray and ultrasound of the lungs for the diagnosis of suspected COVID-19 cases should be carefully interpreted. Future diagnostic accuracy studies should pre-define positive imaging findings, include direct comparisons of the various modalities of interest on the same participant population, and implement improved reporting practices. Planned updates of this review will aim to: increase precision around the accuracy estimates for chest CT (ideally with low risk of bias studies); obtain further data to inform accuracy of chest X-rays and ultrasound; and obtain data to further fulfil secondary objectives (e.g. 'threshold' effects, comparing accuracy estimates across different imaging modalities) to inform the utility of imaging along different diagnostic pathways.Copyright © 2020 The Authors. Cochrane Database of Systematic Reviews published by John Wiley & Sons, Ltd. on behalf of The Cochrane Collaboration.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.