Multicenter Study
Multi-center implementation of automated age-adjusted D-dimer results reduces unnecessary PE imaging.
- Jeffrey Dubin, Mary Kathleen Ratay, Matt Wilson, Peter Davis-Allen, Michael Gillam, Joseph Izzo, Kevin Maloy, Jonathan Davis, and Munish Goyal.
- MedStar Washington Hospital Center, Department of Emergency Medicine, United States of America; Georgetown University School of Medicine, United States of America.
- Am J Emerg Med. 2021 Feb 1; 40: 181-183.
BackgroundSeveral previous studies have investigated the clinical utility of age-adjusted D-dimer cutoffs for diagnosing pulmonary embolism (PE).ObjectivesWe performed a pre/post implementation study, using data from a mid-Atlantic healthcare system comprising 6 hospitals and 400,000 ED visits to determine whether implementing age adjusted D-dimer cutoffs reduced the number of imaging tests performed.MethodsRetrospective study of all patients who had a D-dimer performed during ED visits between September 2015 to September 2018. On March 21, 2017, the D-dimer upper limit of normal system-wide was increased for patients over 50 to: Age (years) x 0.01μg/mL. D-dimer results were displayed as normal or high based on automated age adjustment. EHR Chart review was performed 1.5 years prior to implementation of age-adjusted D-dimer cutoffs, as well as 1.5 years after to evaluate mortality and test accuracy characteristics such as false negative rates. Comparisons were made using chi-square testing.Results22,302 D-dimers were performed pre-implementation of which 10,837 (48.6%) were positive resulting in 7218 (32.3%) imaging studies. After implementation of age-adjusted d-dimer, 25,082 were performed of which 10,851 (43.2%) were positive resulting in 7017 (28.0%) imaging studies. (pre: 48.6%, post: 43.2%; p < 0.01). A significantly lower proportion of patients had a positive d-dimer (pre: 48.6%, post: 43.2%; p < 0.01) and underwent imaging post-implementation (pre: 32.3%, post: 28.0%; p < 0.05) a relative risk reduction of 13.3. This absolute risk reduction of 4.4% is associated with 1104 less scans in the post-implementation group while still increasing test accuracy from 53.7% to 59.2% (p < 0.05).ConclusionImplementation of an automated age-adjusted D-dimer positive reference value reduced CT and V/Q imaging in this population by 4.4% while increasing test accuracy in a regional, heterogeneous six-hospital system.Copyright © 2020. Published by Elsevier Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.