• J. Card. Fail. · Sep 2008

    Comparative Study

    Echocardiography-guided pacemaker optimization and radial artery tonometry.

    • Tasneem Z Naqvi and Asim M Rafique.
    • Cardiac Non Invasive Laboratory, Cedars-Sinai Medical Center, UCLA David Geffen School of Medicine, Los Angeles, CA 90033, USA.
    • J. Card. Fail. 2008 Sep 1; 14 (7): 583-9.

    BackgroundBiventricular (Biv) pacemaker optimization is underused because of time and echo skill required. We evaluated radial artery tonometry during echo-guided Biv optimization of atrioventricular (AV) and interventricular (VV) delays.Methods And ResultsA total of 60 patients (67 +/- 10 years) underwent simultaneous radial artery tonometry and echocardiography after Biv implant at baseline, short AV delay, and optimal AV delay. Twenty of these also underwent VV optimization. Optimal AV delay was determined by ejection duration (E-dur) of left ventricular (LV) outflow tract by pulsed-waved (PW) Doppler (LV(E-dur)) and mitral inflow PW Doppler pattern and optimal VV delay by LV(E-dur) and tissue Doppler. E-dur was also measured from radial artery pulse wave (RA(E-dur)). AV optimization improved LV(E-dur) from 249 +/- 35 to 260 +/- 38 ms (P < .01) and RA(E-dur) from 276 +/- 31 ms to 284 +/- 32 ms (P = .02). Correlation between LV(E-dur) and by RA(E-dur) was 0.83 (95% CI 0.75-0.92). RA(E-dur) was 282.53 +/- 30 at baseline, 286.65 +/- 36 at optimal AV delay (P < .04 vs. baseline) and 286.90 +/- 35 ms (P < .04 vs. baseline) at optimal AV and VV delay in those who underwent VV optimization.ConclusionsAV and VV optimization by echocardiography produces significant improvement in LV(E-dur) and RA(E-dur). Radial artery tonometry may provide a simple noninvasive method to assist in AV delay optimization.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.