-
- Cameron R Smith, Nikolaus Gravenstein, Thomas E LeMaster, Ceri M Borde, and Brenda G Fahy.
- Department of Anesthesiology, University of Florida College of Medicine, Gainesville, Florida.
- Respir Care. 2020 Dec 1; 65 (12): 1923-1932.
BackgroundExposure of respiratory therapists (RTs) during aerosol-generating procedures such as endotracheal intubation is an occupational hazard. Depending on the hospital, RTs may serve as laryngoscopist or in a role providing ventilation support and initiating mechanical ventilation. This study aimed to evaluate the potential exposure of RTs serving in either of these roles.MethodsWe set up a simulated patient with severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection in an ICU setting requiring endotracheal intubation involving a laryngoscopist, a nurse, and an RT supporting the laryngoscopist. All participants wore appropriate personal protective equipment (PPE). A fluorescent marker was sprayed by an atomizer during the procedure using 3 different methods for endotracheal intubation. The 3 techniques included PPE alone, a polycarbonate intubating box, or a coronavirus flexible enclosure, which consisted of a Mayo stand with plastic covering. The laryngoscopist and the supporting RT were assessed with a black light for contamination with the fluorescent marker. All simulations were recorded.ResultsWhen using only PPE, both the laryngoscopist and the RT were grossly contaminated. When using the intubating box, the laryngoscopist's contamination was detectable only on the gloves: the gown and face shield remained uncontaminated; the RT was still grossly contaminated on the gloves, gown, neck, and face shield. When using the coronavirus flexible enclosure system, both the laryngoscopist and the RT were better protected, with contamination detected only on the gloves of the laryngoscopist and the RT.ConclusionsOf the 3 techniques, the coronavirus flexible enclosure contained the fluorescent marker more effectively during endotracheal intubation than PPE alone or the intubating box based on exposure of the laryngoscopist and supporting RT. Optimizing containment during aerosol-generating procedures like endotracheal intubation is a critical component of minimizing occupational and nosocomial spread of SARS-CoV-2 to RTs who may serve as either the laryngoscopist or a support role.Copyright © 2020 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.