-
Journal of neurosurgery · Oct 2015
High-fidelity virtual stenting: modeling of flow diverter deployment for hemodynamic characterization of complex intracranial aneurysms.
- Jianping Xiang, Robert J Damiano, Ning Lin, Kenneth V Snyder, Adnan H Siddiqui, Elad I Levy, and Hui Meng.
- Toshiba Stroke and Vascular Research Center.
- J. Neurosurg. 2015 Oct 1; 123 (4): 832-40.
ObjectFlow diversion via Pipeline Embolization Device (PED) represents the most recent advancement in endovascular therapy of intracranial aneurysms. This exploratory study aims at a proof of concept for an advanced device-modeling tool in conjunction with computational fluid dynamics (CFD) to evaluate flow modification effects by PED in actual, treated cases.MethodsThe authors performed computational modeling of 3 PED-treated complex aneurysm cases. The patient in Case 1 had a fusiform vertebral aneurysm treated with a single PED. In Case 2 the patient had a giant internal carotid artery (ICA) aneurysm treated with 2 PEDs. Case 3 consisted of tandem ICA aneurysms (III-a and III-b) treated by a single PED. The authors' recently developed high-fidelity virtual stenting (HiFiVS) technique was used to recapitulate the clinical deployment process of PEDs in silico for these 3 cases. Pretreatment and posttreatment aneurysmal hemodynamics studies performed using CFD simulation were analyzed. Changes in aneurysmal flow velocity, inflow rate, wall shear stress (WSS), and turnover time were calculated and compared with the clinical outcome.ResultsIn Case 1 (occluded within the first 3 months), the aneurysm had the most drastic flow reduction after PED placement; the aneurysmal average velocity, inflow rate, and average WSS were decreased by 76.3%, 82.5%, and 74.0%, respectively, whereas the turnover time was increased to 572.1% of its pretreatment value. In Case 2 (occluded at 6 months), aneurysmal average velocity, inflow rate, and average WSS were decreased by 39.4%, 38.6%, and 59.1%, respectively, and turnover time increased to 163.0%. In Case 3, Aneurysm III-a (occluded at 6 months) had a decrease by 38.0%, 28.4%, and 50.9% in average velocity, inflow rate, and average WSS, respectively, and turnover time increased to 139.6%, which was quite similar to Aneurysm II. Surprisingly, the adjacent Aneurysm III-b had more substantial flow reduction (a decrease by 77.7%, 53.0%, and 84.4% in average velocity, inflow rate, and average WSS, respectively, and an increase to 213.0% in turnover time) than Aneurysm III-a, which qualitatively agreed with angiographic observation at 3-month follow-up. However, Aneurysm III-b remained patent at both 6 months and 9 months. A closer examination of the vascular anatomy in Case 3 revealed blood draining to the ophthalmic artery off Aneurysm III-b, which may have prevented its complete thrombosis.ConclusionsThis proof-of-concept study demonstrates that HiFiVS modeling of flow diverter deployment enables detailed characterization of hemodynamic alteration by PED placement. Posttreatment aneurysmal flow reduction may be correlated with aneurysm occlusion outcome. However, predicting aneurysm treatment outcome by flow diverters also requires consideration of other factors, including vascular anatomy.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.