- Gennaro Martucci, Giovanna Panarello, Giovanna Occhipinti, Giuseppe Raffa, Fabio Tuzzolino, Guido Capitanio, Tiziana Carollo, Giovanni Lino, Alessandro Bertani, Patrizio Vitulo, Michele Pilato, Roberto Lorusso, and Antonio Arcadipane.
- Department of Anesthesia and Intensive Care, IRCCS - ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione), Palermo, Italy.
- J Thorac Dis. 2018 Oct 1; 10 (10): 5813-5821.
BackgroundTechnological improvement has contributed to making veno-venous extracorporeal membrane oxygenation (VV-ECMO) safer and easier, spreading its use in acute respiratory failure (ARF).MethodsThis is a retrospective observational study carried out in the ECMO center at IRCCS-ISMETT, a medical center focused on end-stage organ failure treatment in Italy. We investigated the effect of different cannula designs on the amount of blood product transfused. Eighty-nine consecutive patients affected with ARF on VV-ECMO from 2008 to 2016 were compared according to type of cannulation: older percutaneous cannula (Standard group, 52 patients) and HLS© BIOLINE-coated, but with shorter drainage cannula (BIOLINE group, 37 patients).ResultsThe two study groups were comparable in terms of baseline characteristics [age, body mass index (BMI), Simplified Acute Physiology Score (SAPS-II), Sequential Organ Failure Assessment (SOFA), Predicting Death For Severe ARDS on VV-ECMO (PRESERVE) score] and ECMO management [median hematocrit (Htc), platelet nadir, antithrombin III (AT III), heparin, activated partial thromboplastin time (APTT)]. In the BIOLINE group, a lower amount of packed red blood cells (pRBC) was transfused considering both total number [4 units, interquartile range (IQR) 1-9 vs. 12 units, IQR 5.5-21; P<0.01] and mL of pRBC/day of ECMO support (91, IQR 21-158 vs. 193.5, IQR 140.5-254; P<0.01). In the BIOLINE group, a trend in reduction of ECMO days (P=0.05) and length of intensive care unit (ICU) stay was found (P=0.06), but no differences in rates of ECMO weaning and ICU discharge were evidenced. The BIOLINE group constituted a saving of €1,295.20 per patient/treatment, counting the costs for cannulation and pRBC administration.ConclusionsMore biocompatible and shorter drainage cannula may represent one of the contributing factors to a reduction in transfusions and costs of VV-ECMO in the current ongoing technological improvement in ECMO.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.