• J Clin Sleep Med · Mar 2016

    Randomized Controlled Trial Multicenter Study

    Impact of Randomization, Clinic Visits, and Medical and Psychiatric Cormorbidities on Continuous Positive Airway Pressure Adherence in Obstructive Sleep Apnea.

    • Rohit Budhiraja, Clete A Kushida, Deborah A Nichols, James K Walsh, Richard D Simon, Daniel J Gottlieb, and Stuart F Quan.
    • Division of Sleep and Circadian Disorders, Brigham and Women's Hospital and Division of Sleep Medicine, Harvard Medical School, Boston, MA.
    • J Clin Sleep Med. 2016 Mar 1; 12 (3): 333-41.

    Study ObjectivesTo evaluate factors associated with continuous positive airway pressure (CPAP) adherence in patients with obstructive sleep apnea (OSA) in the Apnea Positive Pressure Long-term Efficacy Study (APPLES) cohort.MethodsThe data from a prospective 6-mo multicenter randomized controlled trial with 558 subjects randomized to active CPAP and 547 to sham CPAP were analyzed to assess adherence to CPAP during first 2 mo (early period) and during months 5-6 (late period).ResultsParticipants randomized to active CPAP had higher hours of nightly adherence compared to the sham CPAP group at both 2 (4.9 ± 2.0 h versus 4.07 ± 2.14 h, p < 0.001) and 6 mo (4.70 ± 2.08 h versus 3.41 ± 2.19 h, p < 0.001). Those assigned to sham CPAP were more likely to correctly identify their treatment group (70.0% versus 55.2%, p < 0.001). Irrespective of treatment group assignment, those who believed they were receiving active CPAP had higher hours of adherence than those who thought they were in the sham CPAP group at both 2 mo (4.91 ± 2.01 versus 4.17 ± 2.17, p < 0.001) and 6 mo (4.65 ± 2.10 versus 3.65 ± 2.22, p < 0.001). Among those randomized to active CPAP, older age was significantly related to CPAP use > 4 h per night. Presence of cardiovascular disorders was associated with higher hours of CPAP use, whereas presence of anxiety was associated with a trend toward lower hours of CPAP use. Presence of nasal congestion was associated with a decrease in mean daily CPAP use between the early and the late adherence period. The adherence during the week prior to a clinic visit was higher than the average adherence during the 2-mo period prior to the visit.ConclusionsRandomization to active therapy, belief that one is in the active treatment group, older age, and possibly presence of cardiovascular disorders are positively linked to CPAP adherence. Nasal congestion and anxiety are negatively associated with CPAP adherence. CPAP nightly usage increases as clinic visits approach.© 2016 American Academy of Sleep Medicine.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…