J Clin Monit Comput · Apr 2012
Comparative StudyNoninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry.
- Ron Dueck, Oliver Goedje, and Paul Clopton.
- Anesthesiology Service, Veterans Affairs San Diego Healthcare System, San Diego, CA, USA. rdueck@vapop.ucsd.edu
- J Clin Monit Comput. 2012 Apr 1;26(2):75-83.
AbstractThe Tensys TL-200(®) noninvasive beat-to-beat blood pressure (BP) monitor displays continuous radial artery waveform as well as systolic, mean and diastolic BP from a pressure sensor directly over the radial artery at the wrist. It locates the site of maximal radial pulse signal, determines mean BP from maximal pulse waveform amplitude at optimal artery compression and then derives systolic and diastolic BP. We performed a cross-sectional study of TL-200 BP comparisons with contralateral invasive radial artery (A-Line) BP values in 19 subjects during an average 2.5 h of general anesthesia for a wide range of surgical procedures. Two hundred and fifty random sample pairs/patient resulted in 4,747 systolic, mean and diastolic BP pairs for analysis. A-Line BP ranged from 29 mm Hg diastolic to 211 mm Hg systolic, and heart rate varied between 38 and 210 beats/min. Bland-Altman analysis showed an average 2.3 mm Hg TL-200 versus A-Line systolic BP bias and limits of agreement (1.96 SD) were ± 15.3 mm Hg. Mean BP showed a 2.3 mm Hg TL-200 bias and ± 11.7 mm Hg limits of agreement, while diastolic BP showed a 1.7 mm Hg bias and ± 12.3 mm Hg limits of agreement. Coefficients of determination for TL-200 and A-Line BP regression were r² = 0.86 for systolic, r² = 0.86 for mean, and r² = 80 for diastolic BP, respectively, with no apparent change in correlation at low or high BP. Bland-Altman analysis suggested satisfactory agreement between TL-200 noninvasive beat-to-beat BP and invasive A-Line BP. Paired TL-200/A-Line BP comparisons showed a high coefficient of determination.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.