• Spine · Mar 2021

    Biomechanical Evaluation of a Dynamic Stabilization System for the Prevention of Proximal Junctional Failure in Adult Deformity Surgery.

    • Alex S Ha, Daniel Y Hong, Josephine R Coury, Andrew J Luzzi, Alex L Yerukhimov, Jisoo Kim, Peng Huang, and Dilip K Sengupta.
    • The Spine Hospital, New York-Presbyterian/Columbia University Irving Medical Center, New York, NY.
    • Spine. 2021 Mar 15; 46 (6): E356-E363.

    Study DesignBiomechanical spine model. Comparison of stress in the implant and the adjacent cranial segment was done with conventional rigid versus dynamic stabilization system (DS) fixation.ObjectiveThe aim of this study was to study stress at the proximal end of spinal fixation with a novel DS.Summary Of Background DataHigh stress at the implant bone junction may cause proximal junctional failure (PJF) in adult deformity surgery.MethodsFive life-size spine models were instrumented with pedicle screws and a 5.5-mm Titanium rod from T8-S1. The same models were subsequently instrumented with a similar rod and DS between T8-9 pedicle screws. The spine model was loaded with 25 Nm static load cranial to the proximal fixation in six directions. Strains were measured from the proximal screws. Disc pressure was measured from the proximal instrumented segment (T8-9) and cranial adjacent segment (T7-8).ResultsRigid fixation produced highest strain at T8, followed by T10 then T9. In contrast, DS fixation produced highest strain at T10, followed by T9 then T8. Strain at T8 was significantly less with DS fixation than rigid fixation (P = 0.019). The T10 screw strain was not significantly higher with DS stabilization compared to rigid fixation (P = 0.091). Rigid fixation allowed no load-sharing or pressure rise at T8-9 but an abrupt rise at T7-8. DS system permitted load-sharing and pressure rise in T8-9; the difference compared to rigid fixation was significant in flexion loading (P = 0.04) and similar trend but not significant in extension (P = 0.09). DS system produced a rise in the adjacent segment disc pressure (T7-8), which was smaller than rigid fixation but not significant.ConclusionLong spinal fixation using rigid rods produces maximum stress at the proximal end screw and increases adjacent disc pressure, possibly leading to PJF. Dynamic stabilization at the cranial end segment may prevent PJF by reducing these factors.Level of Evidence: N/A.Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…